Recommendation of Scanning Vibrating Electrode Technique (SVET) to Standardized Draft "guide to in Vitro Degradation Testing of Absorbable Metals"
Liu Yang,Cheng Yan,Zheng Yufeng
DOI: https://doi.org/10.3389/conf.fbioe.2016.01.01824
IF: 5.7
2016-01-01
Frontiers in Bioengineering and Biotechnology
Abstract:Event Abstract Back to Event Recommendation of scanning vibrating electrode technique (SVET) to standardized draft "guide to in vitro degradation testing of absorbable metals" Yang Liu1*, Yan Cheng2 and Yufeng Zheng1, 2 1 Peking University, Department of Materials Science and Engineering, College of Engineering, China 2 Peking University, Center for Biomedical Materials and Tissue Engineering, Academy for AdvancedInterdisciplinaryStudies, China Introduction: Biodegradable Metals (also known as absorbable metals) have attracted great attention for their unique degradation properties[1]. The biggest challenge nowadays is to well understand the degradation and then tailor the degradation according to host environment. According to the discussed guide at at BIOMETALS 2015, currently the evaluation methods upon corrosion tests include electrochemical tests, immersion test and hydrogen evolution test[2]. Despite investigating instantaneous data or not, these degradation test methods all record the data of the large area of the exposured surface. However, localized corrosion and pitting corrosion are more detrimental to medical devices. Besides, it's been generally accepted that rate uniformity is considered to be the princeple concern. Therefore in situ monitoring localized corrosion/pitting corrosion along with time is in great demand. Here we propose SVET (scanning vibrating electrode technique) to monitor the corrosion process, getting localized corrosion/ pitting corrosion data instantaneously. Materials and Methods: As-cast Mg-6Zn and Mg-2Sr were utilized. The materials have been mechanically polished up to 5000 grit and polished by electrichemical method. The microstructure was investigated via metalloscope. SVET test (Applicable Electronics Inc, USA) was carried out in Hank's solution. Pt-Ir wire probe as microelectrode was located 2000 um above the specimen to reduce the influence of hydrogen from the surface. SVET monitoring was conducted for 2 h. Results and Discussion: Figure 1 shows the microstructure and the corresponding SVET monitored corrosion current density distribution at 5 min. The grain boundary and the aggregates of second phase inside the grain define the corrosion current density range. Some particles in the grains possess cathodic corrosion current density, while some other particles and the grain boundaries perform anodic corrosion current density. This may be due to different Mg-Zn intermetallics and the impurities. Thereafter, the area where perform extremum in corrosion current density experience typical routine. SVET monitored corrosion rate continually increasing, and then slow down. Meanwhile, other parts of the surface randomly reach its highest corrosion current density and then decrease. Figure 1. Microstructure and the corresponding SVET corrosion current density distribution of as-cast Mg-6Zn at 5 min in Hank's solution. Figure 2 shows the microstrucuture and the corresponding SVET monitored corrosion current density distribution at 5 min. Sr is more active than Zn and it possesses a much lower solubility in Mg. High activety of Mg-Sr alloy leads to both high cathodic and high anodic corrosion current density. The local corrosion can even reach its highest corrosion rate of 500 μA·cm-2. Figure 2. Microstructure and the corresponding SVET corrosion current density distribution of as-cast Mg-2Sr at 5 min in Hank's solution. Conclusions: SVET makes in situ monitoring of local/pitting corrosion possible. It can help get a comprehensive depiction of the surface corrosion performance along with time, which can not be gotten by current-applied corrosion testing methods. Since localized corrosion and pitting corrosion are common but critical in biodegradable Mg alloys, we strongly recommend the apply of SVET/SIET as standard evaluation method for biodegradable metal corrosion. National Basic Research Program of China (973 Program) (Grant No. 2012CB619102), National Science Fund for Distinguished Young Scholars (Grant No. 51225101), National Natural Science Foundation of China (Grant No. 51431002 and 31170909)References:[1] Y.F. Zheng, X.N. Gu, F. Witte, Biodegradable metals, Materials Science and Engineering: R: Reports, 77 (2014) 1-34.[2] Standard Guide to In vitro Degradation Testing of Absorbable Metals. Biometals, 2015. Keywords: in vitro, corrosion, Biodegradable metal, biodegredation Conference: 10th World Biomaterials Congress, Montréal, Canada, 17 May - 22 May, 2016. Presentation Type: New Frontier Oral Topic: Safety and toxicity evaluation for biomaterials Citation: Liu Y, Cheng Y and Zheng Y (2016). Recommendation of scanning vibrating electrode technique (SVET) to standardized draft "guide to in vitro degradation testing of absorbable metals". Front. Bioeng. Biotechnol. Conference Abstract: 10th World Biomaterials Congress. doi: 10.3389/conf.FBIOE.2016.01.01824 Copyright: The abstracts in this collection have not been subject to any Frontiers peer review or checks, and are not endorsed by Frontiers. They are made available through the Frontiers publishing platform as a service to conference organizers and presenters. The copyright in the individual abstracts is owned by the author of each abstract or his/her employer unless otherwise stated. Each abstract, as well as the collection of abstracts, are published under a Creative Commons CC-BY 4.0 (attribution) licence (https://creativecommons.org/licenses/by/4.0/) and may thus be reproduced, translated, adapted and be the subject of derivative works provided the authors and Frontiers are attributed. For Frontiers’ terms and conditions please see https://www.frontiersin.org/legal/terms-and-conditions. Received: 27 Mar 2016; Published Online: 30 Mar 2016. * Correspondence: Dr. Yang Liu, Peking University, Department of Materials Science and Engineering, College of Engineering, Beijing, China, liuyang_0320@163.com Login Required This action requires you to be registered with Frontiers and logged in. To register or login click here. Abstract Info Abstract The Authors in Frontiers Yang Liu Yan Cheng Yufeng Zheng Google Yang Liu Yan Cheng Yufeng Zheng Google Scholar Yang Liu Yan Cheng Yufeng Zheng PubMed Yang Liu Yan Cheng Yufeng Zheng Related Article in Frontiers Google Scholar PubMed Abstract Close Back to top Javascript is disabled. Please enable Javascript in your browser settings in order to see all the content on this page.