The Research and Realization of Calibration Temperature Selection on Two-point Non-Uniformity Correction

XIA Mei,GU Guo-hua,CHEN Qian,SUI Xiu-bao
DOI: https://doi.org/10.3969/j.issn.1001-8891.2011.03.006
2011-01-01
Abstract:In view of the lack of precision and small dynamic range in two-point non-uniformity correction,firstly,we research on the "S" model of the actual response of the focal plane detector and introduce the method of two-point correction.Then,the relationship between the selection of the calibration temperature and the accuracy and the dynamic range is elaborated,and the calibration temperature selection method based on dichotomy is proposed.At last,the proposed method is realized by FPGA and DSP.It is proved that this method ensures the advantages of real-time processing and simple algorithm while improving the accuracy of the Two-point correction and enlarging dynamic range.