The Non-Uniform Analysis In The Infrared Imaging System

Zm Wu,Qf Liu,Lm Zhou,Y Liu,Yd Jiang
2004-01-01
Abstract:The non-uniformity in detector cell leads to the big nonlinear distortion of picture. In order to improve the quality of the picture, the non-uniform of the picture must been corrected. In the methods of non-uniform correction, the advantage of two-temperature point correction arithmetic is with small calculating amount. it is the real time correction method of the picture cell. Emulation result is shown that the response output of the picture can be corrected goodly by two-point temperature correction arithmetic.Matlab emulates the system of the uncooled infrared focal plane array in this paper. It is concluded that the two-point correction arithmetic can satisfied the system of normal picture quality. However, substrate temperature influenced the precision of the two-point correction arithmetic, this make this correction method only fit for narrow range of temperature and work state. The precision of the two-temperature point correction arithmetic is very badly when the nonlinear is very strongly. The two-temperature point correction method is proper for the infrared focal plane array with the weakly nonlinear system and the little dynamic range. The error of the two-point correction arithmetic and the reason of the output signal's non-uniform is analyzed in this paper, the better method that the error of the two-temperature point correction arithmetic was decreased was put forward. The two-temperature point correction arithmetic is implemented by FPGA.
What problem does this paper attempt to address?