Improving the biofouling resistance of polyamide thin-film composite membrane via grafting polyacrylamide brush on the surface by in-situ atomic transfer radical polymerization
Man Zhao,Yang Yang,Hui Yu,Xiaotai Zhang,Xinxia Tian,Shancan Fu,Huifeng Zhang
DOI: https://doi.org/10.1016/j.memsci.2021.119283
IF: 9.5
2021-07-01
Journal of Membrane Science
Abstract:<p>Membrane biofouling represents a major challenge ever-present in the practical application of polyamide (PA) thin-film composite (TFC) reverse osmosis (RO) membranes. This work focused on grafting polyacrylamide (PAAm) onto PA-TFC <em>via</em> an <em>in-situ</em> atomic transfer radical polymerization (ATRP) method to improve the biofouling resistance of PA-TFC. The ATRP initiators, isobutyryl bromide (<em>i</em>PB), were introduced into PA matrix using a bifunctional small molecule, 2-bromoisobutyryl bromide (BIBB), added in organic hexane solutions to participate in interfacial polymerization through the condensation reaction with <em>m</em>-phenylenediamine. The successful introduction of <em>i</em>PB was confirmed by membrane surface characterizations, and the <em>i</em>PB density in PA layer was tuned by varying the BIBB concentrations in hexane solutions based on the variation in water permeance and salt rejections of <em>i</em>PB-loaded PA-TFC. The ATRP for the gradual growth of PAAm brush was thus <em>in-situ</em> achieved on the PA-TFC surface from the pre-incorporated <em>i</em>PB groups and the length of PAAm chains was facilely controlled <em>via</em> tuning ATRP polymerization time. The PAAm grafted PA-TFC exhibited a minimum decrement of water permeance and essentially retained salt rejections relative to the un-grafted ones. More importantly, the grafted membranes presented synergistically enhanced anti-adhesion and bacteriostatic performance towards either Gram-negative <em>Escherichia coli</em> (<em>E</em>. <em>coli</em>) or Gram-positive <em>Bacillus subtilis</em> (<em>B. subtilis</em>). Also, the grafted membranes presented a lower final flux decline ratio (FDR<sub><em>f</em></sub>) and higher final flux recovery ratio (FRR<sub><em>f</em></sub>) in relation with the un-grafted membranes in the dynamic bovine serum albumin (BSA) fouling test. Particularly, the membrane grafted with longer PAAm chains from extended grafting time showed better anti-biofouling performance: the sterilization ratio towards <em>E. coli</em> and <em>B. subtilis</em> achieved up to 98.8% and 99.0%, respectively, and FDR<sub><em>f</em></sub> of just 3.7% and FRR<sub><em>f</em></sub> of 97.6% after 3 × 8 h BSA fouling test for the membrane subjected to 2 h ATRP grafting. The PAAm grafting induced greater water wettability of membrane surface and the flexible chain structure of PAAm were proposed to account for the enhanced anti-adhesion and bacteriostasis towards bacteria, which collaboratively led to the improved biofouling resistance.</p>
engineering, chemical,polymer science