Study on Applying CDAG to Core Damage Assessment for the Large Break Severe LOCA Accident of Qinshan Ⅱ

魏玮,周志伟
DOI: https://doi.org/10.3321/j.issn:0258-0918.2008.04.009
2008-01-01
Abstract:The paper applied MELCOR1.8.5 to analyze the large break severe LOCA accidentwithout mitigatory measures for Qinshan Ⅱ,and adopted the Westinghouse Owners Group Core Damage Assessment Guidance(CDAG)to estimate the status and extent of the core damage in the early phase of the accident.The analysis results of the core damage status and extent before the failure of the bottom head of the reactor vessel have shown that CDAG can reasonably evaluate the core damage status and extent,which are significant value for further study and validate the comprehensive assessment capability and applicability of CDAG.
What problem does this paper attempt to address?