3D Thermal-Magnetic Field Calculation of Transformer Using FEM

LI ji,LUO Long-fu,XU Jia-zhu,LI Yong
DOI: https://doi.org/10.3969/j.issn.1003-8930.2007.01.019
2007-01-01
Abstract:To improve the calculating precision of leakage magnetic field of high leakage reactance and multi-winding main transformer of electric locomotive,the finite-element thermal-magnetic calculation model and physical equations of oil tank in main transformer of electric locomotive are founded in this paper.The loss of tank is calculated with 3D FEM based on edge element.The 3D thermal field of the tank before and after taking shielding measure is also analyzed with FEM and weak coupled magnetic-thermal field method.The measured value of the tank loss is 31.245kW while the calculation result is 30.478kW by 3D FEM.It is also found that the maximum temperature of copper shields in both left and right are all reduced by 3℃.Temperature in the space distributes more uniformly,local hot-spot can be avoided and loss can be decreased.The calculation can also give a set of useful parameters for the design of main transformer of electric locomotive.
What problem does this paper attempt to address?