Application of Plasma Current Protection in Controlling System of EAST Tokamak

CHAO Hui-li,XIAO Bing-jia,JI Zhen-shan
DOI: https://doi.org/10.3969/j.issn.2095-6835.2010.28.014
2010-01-01
Abstract:EAST(Experimental Advanced of conducting Tokamak)is the first superconducting Tokamak device system in the world studied and developed by our country.The superconducting Tokamak system boasts unique running characteristics and higher running risks.Thus,it needs more rigorous and effective protecting system.The plasma current cut-off system introduced in the paper possesses the function of plasma current-detecting.When plasma cuts off unexpectedly due to some abnormity of plasma,such as breaking,the system protects PF Magnet Power Supply(MPS),magnet and EAST device on time,by making MPS and the microwaveheating system exit in the fast model rather than keeping working.The system has been successfully applied in the EAST experiment in April,2009.