Pilot-plant Test Study on Treating Coking Wastewater with Double-Membranes Method

ZHOU Chao,GAO Xue-li,GUO Xi-liang,LI Sai-sai,GAO Cong-jie
DOI: https://doi.org/10.3969/j.issn.0253-4320.2012.08.022
2012-01-01
Abstract:Coking wastewater is treated with double-membranes method,which consists of settling system,ultrafiltration(UF) system and reverse osmosis(RO) system.Settling system is applied with underbrush to ensure the water quality of UF system.During the whole test period,the quality index of the ultrafiltered water is shown as follows:SDI153,turbidity0.2 NTU and free chloride0.05 mg/L,which meets the requirement of the inlet water of RO system.After RO treatment,the water quality index of treated water can reach the expected one for pilot-plant test,that is,COD5 mg/L and about 30 μS/cm of conductivity.UF membrane model is washed with caustic and acid solutions twice during the period.The permeate flux can return to the original value.In the pilot-plant test,RO system runs stably and efficiently.
What problem does this paper attempt to address?