Numerical Simulation on Lag Water-Bursting at Fault Zone Based on FLAC~(3D)

刘伟韬,申建军,王连富
DOI: https://doi.org/10.3969/j.issn.1008-0562.2012.05.019
2012-01-01
Abstract:The huge thick layer of ordovician limestone aquifer underlying the coal beds in Northern China coal field is the main water source in deep mining operation with a high pressure, and a large quantity in dynamic-static state. The fault F 0 was investigated in this study as it has a better water conductivity and may form a main water channel to Fangezhuang Colliery in Kailuan. The study obtains the mechanical parameters of fault F 0 using creep mechanics test. In addition, the fluid-solid interaction simulation and the seepage-creep calculation were conducted with FLAC 3D . The simulation results show that the affected zone of coal seam roof under mining is obviously developed on both sides of the fault while the hanging wall displacement is smaller than foot wall displacement. As to the floor strata, the vertical displacement of hanging wall is larger than that of the foot wall while the maximum vertical displacement of roof and floor strata occurs near the fault. The dissection of fracture structure creates a wide range shear stress area at the floor when the floor is subjected to large tectonic stress. The stress concentration is critical to the floor failure and water inrush. The study results have some guiding significance for effectively preventing lag water-bursting at fault zone.
What problem does this paper attempt to address?