RESEARCH ON ELEVATED-TEMPERATURE FRACTURE TOUGHNESS OF INCOLOY 800H MATERIAL FOR IN-SERVICE FURNACE TUBES

Zhang Zhongzheng,Gong Jianming,Tu Shandong
DOI: https://doi.org/10.3969/j.issn.1002-106x.2006.10.008
2006-01-01
Abstract:The elevated-temperature fracture toughness of Incoloy 800H material for in-service furnace tubes was studied at temperature of 550℃and 680℃. The research shows that the elevated-temperature fracture toughness of Incoloy 800 H material for in-service furnace tubes falls down with rising temperature. The fracture toughness is 80 ~ 100 kJ/m at 680℃and higher at 550℃. The test results provide an important basis for the safety assessment of short-term elevated-temperature fracture of in-service furnace tubes.
What problem does this paper attempt to address?