Numerical Simulation of the Thermal Load and Deformation Tendency of a 1100 T/h Tower Furnace Water Wall

董陈,窦文宇,周屈兰,徐通模
2008-01-01
Abstract:By using a self-developed numerical simulation software,a numerical simulation was conducted of the hot-state aerodynamic field and combustion process in boiler No.1 of Pucheng Power Plant.Moreover,the problem of water wall fracture tendency was explored proceeding from the distribution of water wall thermal loads.The numerical simulation results show that when the jet flow from burner nozzles rotates spirally upward,the furnace flame center will be located excessively high and the temperature deviation at the furnace outlet is comparatively big.When the jet flow from the burner nozzles rotates spirally downward,the furnace flame center will be located at the lower part of the furnace,and the furnace temperature distribution exhibits a relatively good uniformity.The thermal loads of the walls at four sides of the furnace have a very big difference,and the water wall has an uneven thermal expansion at the four corners,thus leading to a relatively big fracture tendency.After the rotating direction of the jet flow from the burner nozzles has been adjusted from upward to downward,the thermal load deviation between the wall surfaces will decrease and the possibility of any water wall fracture diminish.In addition,the thermal load deviation of each furnace wall itself is also very big.If hydrodynamic operating conditions deteriorate,a water-wall deformation may also result.
What problem does this paper attempt to address?