Abstract:In order to solve the problems of the conventional sludge thickening,the flat sheet membrane coupled sludge thickening(MST) was used to thicken sludge,which could not only achieve the sludge thickening but also reuse the effluent from membrane.The influence of operational conditions on MST was examined by employing the methods of orthogonal experiment and analytical hierarchy process.The orthogonal experiment indicated that the influences of operational conditions on the rising velocity of sludge concentrations,effluent quality and membrane fouling were different.The effluent quality was met with the water quality standard for urban miscellaneous water consumption.The results of analytical hierarchy process indicated that the optimized operational conditions of MST were aeration intensity of 1.0 m3/h,membrane flux of 18 L/(m2·h)and the ratio of suction time to stop time of 10 min∶2 min.