Determination of cysteine in complex prescription injection by HPLC

Jin Wenxian,Yan Hui,Liu Heng,Wang Chunlong,Zhao Guangrong
DOI: https://doi.org/10.3969/j.issn.1006-5687.2008.02.006
2008-01-01
Abstract:OBJECTIVE To establish a HPLC method for determining of cysteine in complex prescription injection. METHODS The HPLC was performed on a C18 column (250 mm×4.6 mm,5 μm). Ammonium dihydrogen phosphate-methanol(95:5,pH 5.0)was used as mobile phase with a flow rate of 1.0 ml/min, the sample size was 20 μl and the detection wave was at 220 nm. RESULTS A linear relationship was obtained in the range from 240~560 μg/ml(r=0.999 6),the average recovery was 99.32%(RSD=1.06%,n=9). CONCLUSION The method is convenient,rapid and accuratissime. It can be used for determination of cysteine in complex prescription injection.