HI Concentration of HIx (HI-H2O-I2) Solution in Iodine-Sulfur Water-Splitting Cycle by Electro-Electrodialysis

CHEN Songzhe,ZHANG Ping,YAO Taoying,WANG Laijun,XU Jingming
DOI: https://doi.org/10.3321/j.issn:0253-987x.2008.02.028
2008-01-01
Abstract:Nafion 117CS membrane and electrodes of graphite or activated carbon fiber cloth are adopted to establish electro-electrodialysis(EED) apparatus for concentration of hydriodic acid in HIx phase of IS cycle.The effects of different electrodes,current density,operating time and temperature on the efficiency of EED process are investigated.The concentration effect of HI is strengthened with the increasing current densities in range of 5-20 A/dm2.When graphite plates are adopted as electrodes,the molality of HI in catholyte increases faster than activated carbon fiber cloth to lead to a quite low cell voltage.The increasing EED temperature brings out a lower efficiency of HI concentration,while significantly drops the cell voltage.