Abstract:Sediment in sewers is an important component of combined sewer overflow(CSO) pollutants,and it is of great value to reduce CSO pollutants by controlling the sediment.Perforated pipe was installed in upstream sewer of interception pump station of combined sewer system in order to flush sewer with high pressure jet of above 7.5 m/s.Vortex separator was installed in the interception pump station to separate sediment from the upstream flush fluid.The perforated pipe flush technology could increase SS in sewer flow from 75-170 mg/L to 2 500-3 000 mg/L,and sewer cleaning could be finished within 2 to 3 min for a sewer with a diameter of 400 mm,a length of 40 m and a sediment-thickness of 3 cm.The removal rate of SS by the vortex separator was 55.6%.Routine cleaning of sewer once per two weeks could reduce CSO pollutant of 25%,thus decreasing the pollution load of receiving water body.