Advanced Treatment and Reuse of Dyeing and Printing Wastewater
QI Lu-qing,WANG Xiao-jun,XU Qi-kun
DOI: https://doi.org/10.16606/j.cnki.issn0253-4320.2010.12.022
2010-01-01
Abstract:According to desalination problems of concentrated water treatment in textile dyeing wastewater reuse system,the combined technique of pretreatment system and membrane system are used as the advanced treatment.The pretreatment progress includes integrated device of ozone-biological aerated filter(BAF) and BAF,and the membrane system composed of ultrafiltration(UF) and reverse osmosis(RO).The optimal conditions of pretreatment system are as follows:gas/water ratio is five,organic load is 2.1,1.0 kg(COD)/m3·d respectively,DO,3.8 mg/L,temperature,35-45℃,ozone dosage,20-30 mg/L.After being steadily treated by the pretreatment,COD,turbidity,SS,ammonia nitrogen and color are 27.4 mg/L,4.2 NTU,3.0 mg/L,0.7 mg/L and 2 times respectively.After being steadily treated by the membrane system,permeate water pH value is 7.4-7.9,conductivity,50-200 μs/cm,total hardness,2-10 mg/L,total alkalinity,25-60 mg/L.The results show that the effluent water quality from the membrane system is up to the water reuse standard of the company.The pH value is 7.3-8.3,color,32 times,and COD concentration is 45.7-97.9 mg/L of concentrated water.This indicate that the concentrated water from the membrane system could be discharged directly without additional treatment since it met the discharge standard.