Abstract:We have developed a 26kVA (400V/16V) three-phase HTS transformer cooled by liquid nitrogen. The primary and secondary windings were wound by transposed conductors, which are made from the stainless steel-reinforced multifilamentary Bi2223/Ag tapes. The structures of primary and secondary windings are solenoid and double-pancake respectively. Fundamental characteristics of the transformer are obtained through no-load and short circuit tests. The gas-cooled current leads of secondary windings were optimally designed. The cryostats are made from electrical insulating materials Fiberglass Reinforced Plastics (FRP), which have excellent heat-preservation. The iron cores are made of common scratched Fe-Si steel and operate at room temperature. Based on results of this transformer, we will develop 630 kVA HTS transformer with same rated currents in near future.