Study on legionnella inactivation by silver ion in domestic hot water

Zhao Li,Li Xing,Shen Chen,Fu Wenhua,Xu Bingfeng,Li Jianye,Yang Fan
DOI: https://doi.org/10.3969/j.issn.1002-8471.2013.04.018
2013-01-01
Abstract:The simulated pilot-scale pipeline system was used to study the legionnella and conventional bacteria inactivation by silver ion in domestic hot water.The results showed that the significant inactivation effects to the legionnella and conventional bacterias were achieved by silver ion.The inactivation rate of legionella reached 99.92% after 210 minutes inactivation with 1.20×103 CFU/mL concentration of legionella and 0.10 mg/L concentration of silver ion.After 180 minutes inactivation,the inactivation rate of the total bacterial count reached 97.86% and average inactivation rate of heterotrophic bacteria was 85.71% within the range of 0.05~0.07 mg/L concentration of silver ion.The similar inactivation law and remarkable inactivation effects of the total bacterial count and heterotrophic bacteria were observed in 24 ℃ and 35 ℃ water.It was shown that silver ion could inactivate a wide range of bacteria.The adhesion phenomenon of silver ion on pipe wall and tank wall would damage the continuous inactivation effect.The hysteresis phenomenon of silver ion dosing,adhesion,and disinfection effect should be considered in the design and application of silver ion disinfection device.
What problem does this paper attempt to address?