ANALYSIS AND CONTRAST OF TWO PRESTRESSING STEEL TRUSSES IN COMPOSITE FRAME GIRDER

Zhang Boyi,Zheng Wenzhong,Wang Ying
DOI: https://doi.org/10.3969/j.issn.1007-9963.2007.08.018
2007-01-01
Steel Construction
Abstract:According to the problems from "self-supporting floor system during construction" in reconstruction(extension)project of Suifenhe Qingyun Market,dimension of chord in angle steel truss of encased prestressed steel-truss-concrete composite frame beam is bigger and prestressing tendons are difficult to be tensioned and anchored at the end of the beam,an idea of replacing encased angle steel truss with encased grouted-round-steel tube truss is proposed.Two kinds of encased steel trusses are compared and analyzed,when thickness of steel tube wall equals to thickness of angle steel,diameter of grouted-round-steel tube will be less than depth of angle steel;truss only occupies less space in outer-jacketing column;the steel tube of truss bottom chord can be used for tendon duct for prestressing tendons in straight line,which can facilitate layout,tensioning and anchorage of prestressing tendons.Some research works needing in the future are also pointed out.
What problem does this paper attempt to address?