On the Start-Up of Hybrid Anaerobic Reactor for Mustard Tuber Sewage Treatment
Jian ZHOU,Guo-jun DU,Yong-sheng ZHANG,Xiao-pin LI,Bo CHEN
DOI: https://doi.org/10.3969/j.issn.1009-6094.2011.03.010
2011-01-01
Applied Mechanics and Materials
Abstract:The present paper is to introduce its investigative study on how to solve the slow start-up problem of the hybrid anaerobic reactor for treating the mustard tuber sewage and how to construct a highspeed removing-mierobia systems in the HAR(Hybrid Anaerobic Reactor). The effective volume of the reactor originally was 70 L,with its diameter of 0.3 m,1.2 m of its height,filled with granular activated carbon of diameter of 0.6-0.9 mm.The experimental results show that at the temperature of 20-25 ℃ and the inoculum anaerobic sludge concentration of 30 g/L,the influent mustard tuber sewage tends to keep a salinity of 1.8(Cl~-)loaded with 1.5 kgCOD/(m~3·d),while the removal rate of the reactor was made to complete its start-up in a period of 62 d with its removing efficiency getting up to 90.11%.In such a situation,its reactor can have a sewage-treating power of the influent COD of 4 500 mg/L or that of 440 mg/L at a pH value of 7.3-7.6.At the same time,the device can be made to keep working steadily in a situation with less than 300 mg/L of VFA,1 300-1 500 mg/L of alkalinity and less than-330 mV of ORP.Besides,it was possible for the reactor to shorten the startup time and make the anaerobic biological treating system work at a much greater efficiency.And,in addition,the degradation rate can be made reduced as a result of pushing the COD from its central area to the sixth reaction one.In so doing,the COD load share can be made to reach 5.01 kgCOD/(m~3 · d),2.26 kgCOD/(m~3 · d),1.16 kgCOD/(m~3·d),0.70 kgCOD/(m~3·d),0.75 kgCOD/(m~3 · d), 0.29 kgCOD/(m~3 · d)and 0.20 kgCOD/(m~3 · d),respectively, whereas the COD share removal rate can be made to reach 37.50%, 22.16%,11.36%,6.82%,7.39%,2.84% and 1.93% respectively. The results of the electronic microscope scanning indicate that different dominant microorganisms can be made to appear in the central area and the surrounding areas.Among them,the superior microorganisms of the central area would be methanosarcina and methanobrevibacter ruminatia whereas the first reaction area to the sixth reaction area of the outer ring were likely to be occupied by mainly the methanothrix soehngenii.In this situation,successful application of the sub-classification method can help the reactor to subclassify different cell populations of anaerobic microorganisms and exert its functions to the enhancement of its processing power and operating stability in the most desirable environmental manners.