Self-cleaning Hard Coating of Insulator for the Usage of Anti-pollution Flashover

贾志东,王威,张乾良,邓海辉
2012-01-01
Abstract:We introduced a self-cleaning hard coating(SCHC),and investigated the pollution density on RTV coated insulators after long-term usage.The self-cleaning ability of RTV coating and SCHC was compared by using the micro-glass ball method.The hydrophobicity,the hydrophobicity loss and recovery characteristics as well as the hydrophobicity transference capability were investigated with the contact angle method and the hydrophobicity classification method.The result shows that SCHC absorbs much less pollution particle than RTV.Compared to those of RTV,hydrophobicity and hydrophobicity loss and recovery ability of SCHC are better whereas the hydrophobicity transference ability is equivalent.Therefore,SCHC can notably reduce contamination accumulated on insulator surfaces and prevent pollution flashover.