Optomechanical uncooled infrared imaging system: design, microfabrication, and performance

Yang Zhao,Minyao Mao,R. Horowitz,A. Majumdar,J. Varesi,P. Norton,J. Kitching
DOI: https://doi.org/10.1109/84.993448
2002-01-01
Abstract:This paper presents the design, fabrication and performance of an uncooled micro-optomechanical infrared (IR) imaging system consisting of a focal-plane array (FPA) containing bi-material cantilever pixels made of silicon nitride (SiNx) and gold (Au), which serve as infrared absorbers and thermomechanical transducers. Based on wave optics, a visible optical readout system is designed to simultaneously measure the deflections of all the cantilever beams in the FPA and project the visible deflection map onto a visible charge-coupled device (CCD) imager. The IR imaging results suggest that the detection resolution of current design is 3-5 K, whereas noise analysis indicates the current resolution to be around 1 K. The noise analysis also shows that the theoretical noise-equivalent temperature difference (NETD) of the system can be below 3 mK
What problem does this paper attempt to address?