Bimaterial micro-cantilever uncooled infrared imaging system-design and fabrication of micro-cantilever array

FL Dong,QC Zhang,XP Wu,L Pan,ZY Guo,DP Chen,WB Wang,ZH Duan
DOI: https://doi.org/10.3321/j.issn:1001-9014.2005.06.003
2005-01-01
JOURNAL OF INFRARED AND MILLIMETER WAVES
Abstract:The design and fabrication of one-layer bimaterial micro-cantilever array made of silicon nitride (SiNx) and gold (An) without Si substrate for uncooled optical readout infrared (IR) imaging system were presented. One-layer structure simplifies the fabrication process. IR thermal images can be obtained when the cantilever array is placed in the atmosphere. The experimental results with the micro-cantilever array of 140 x 98 elements and 12-bit CCD indicate that the objects at the temperature of higher than 120 degrees C can be detected and the noise-equivalent temperature difference (NETD) of the device is similar to 7K. The experimental results are well accordant with the thermomechanical design of micro-cantilever array.
What problem does this paper attempt to address?