Divided-fixed Timing Control Method for Auxiliary Resonant Commutated Pole Soft-switching Inverter

MA Ke,XU De-hong,ZHANG Tao
DOI: https://doi.org/10.13334/j.0258-8013.pcsee.2010.18.001
2010-01-01
Abstract:Auxiliary resonant commutated pole(ARCP) is an important soft-switching inverter topology,and the control method for auxiliary switches will impact the inverter's efficiency and reliability.Traditional fixed timing control method for ARCP inverter is relatively simple and easy to be implied.However,the inverter's efficiency performance with fixed timing control is not good enough at lower output power.This paper presented the current stress and loss distributions of ARCP inverter with fixed timing control,and the key method to improve ARCP inverter's efficiency was indicated.Then a novel divided-fixed timing control strategy was proposed,which shows better inverter efficiency without increasing the complexity of controls and sensors.Finally,the evaluation was well verified on a 2 kW/20 kHz ARCP inverter prototype.
What problem does this paper attempt to address?