Research on a Novel High-Efficiency Three-Phase Resonant Pole Soft-Switching Inverter

Qiang Wang,Youzheng Wang
DOI: https://doi.org/10.1109/tpel.2020.3029186
IF: 5.967
2021-05-01
IEEE Transactions on Power Electronics
Abstract:A high-efficiency three-phase resonant inverter is presented to optimize the performance of the inverter. When the auxiliary resonant circuit on each phase bridge arm works in the commutation process of the inverter, the voltage across resonant capacitors in parallel with main switches will form zero state periodically. In this case, main switches can achieve zero-voltage soft-switching. Meanwhile, auxiliary switches can achieve zero-current turn on and zero-voltage turn off during the operation of the auxiliary resonant circuit. Soft-switching can reduce switching loss and make the inverter work efficiently. The novelty of the inverter mainly reflects in the simple structure of the auxiliary circuit and the simple control method of auxiliary switches. This article analyzes the working mode of the circuit and the realization condition of soft-switching. Meanwhile, it discusses theoretical calculation of the power loss of the auxiliary circuit. The experimental results on the 3-kW prototype show that switching devices work in the soft-switching state. The efficiency of the prototype under the rated output power reaches 98.7%, which is higher than that of the same type of other soft-switching inverter. Therefore, the topology is valuable for the research and development of the high-performance three-phase inverter.
engineering, electrical & electronic
What problem does this paper attempt to address?
This paper aims to solve the problem of switching losses in three - phase inverters when operating at high frequencies. Specifically, the paper proposes a new type of high - efficiency three - phase resonant - pole soft - switching inverter to optimize the performance of the inverter. In traditional hard - switching inverters, during the switching process, the voltage and current on the switching devices will overlap, resulting in switching losses. This loss is particularly significant when operating at high frequencies, limiting the high - frequency applications of the inverters. However, soft - switching technology can reduce switching losses and improve the working efficiency of the inverter. The main contributions of the paper are as follows: 1. **Auxiliary circuit with a simple structure**: The auxiliary resonant circuit of each bridge arm has a simple structure, containing only two auxiliary switches, one resonant inductor and three resonant capacitors. In addition, there are no energy - storage capacitors and transformers in the auxiliary circuit, which improves the reliability of the inverter. 2. **Low hardware cost**: The maximum voltage of the main switch does not exceed the DC power supply voltage, avoiding the use of switching devices with higher withstand voltages, thereby reducing the hardware cost. 3. **Simplified control method**: The duty cycle of the trigger pulse of the auxiliary switch can be designed as a fixed value, without the need for real - time detection of the load current, simplifying the control of the auxiliary circuit. 4. **High - efficiency performance**: The experimental results show that the efficiency of the 3 - kW prototype reaches 98.7% at the rated output power, which is higher than other similar soft - switching inverters. Through the above - mentioned design, the paper proposes a new inverter topology suitable for high - efficiency variable - frequency power supplies in electric drive systems, and analyzes in detail its working mode and the conditions for realizing soft - switching, and derives the theoretical expression of the power loss of the auxiliary circuit. Finally, the experimental results verify the performance of this new inverter.