Abstract:Experiments were performed to reveal the influences of operating conditions and throttle opening on working stability of the transcritical CO2 compression-ejection system.Through analysis of the trends in primary flow pressure,entrained flow pressure,back pressure,primary flow rate,entrained flow rate,entrainment ratio,and pressure lift,the following characteristics of system stability were determined.Changes in cooling water flow rate or throttle opening can cause the system to transition from one stable state to another.It can behave in an unstable way during the transition.When the throttle is nearly full open (90%),the primary pressure is near the high-pressure limit.The primary flow reaches choke condition of the compressor.The system becomes unstable and must be shut down.When the throttle opening is nearly full closed (5%),the flow rate of the entrained fluid decreases until to zero.The ejector no longer entrains this fluid.The system becomes unstable and must be shut down.