Experiment on Performance of Transcritical CO_2 Heat Pump Water Heater System with Ejector

Xiaoxiao XU,Guangming CHEN,Liming TANG,Lixia LIANG,Zhijiang ZHU
DOI: https://doi.org/10.3321/j.issn:0253-987X.2009.11.011
2009-01-01
Abstract:An experimental water heater system using a transcritical CO_2 heat pump with an ejec-tor was designed, and a measurement and control system was developed. Experiments were con-ducted to assess the effects of cooling water flow rate and inlet temperature on the system per-formance. The changes of the heating coefficient of performance (C_r), heating capacity, pressure ratio, entrainment ratio, pressure lift were and ejector efficiency were analyzed. The experimen-tal results show that the entrainment ratio and the pressure lift were increased while the ejector efficiency was decreased with the decrease in the cooling water flow rate or the increase in the in-let temperature. Under the experimental working conditions, the ejector efficiency was up to 34%, and the pressure lift was up to 1. 165. The C_r reached about 3.0 when the evaporation tem-perature was -5℃. Compared with that of a conventional system with an expansion valve, the pressure ratio of the compressor in the present water heater system is decreased by 12%-14%. It appears that the ejector can improve the system performance of transcritical CO_2 heat pump water heaters effectively.
What problem does this paper attempt to address?