A/O Hybrid Membrane Bioreactor for High-Loaded Ammonia Wastewater Treatment

YANG Chang-zhu,WANG Xiao-ying,PU Wen-hong,YANG Qun,CHEN Jian-ping
DOI: https://doi.org/10.3969/j.issn.2095-0985.2006.04.009
2006-01-01
Journal of Huazhong University of Science and Technology
Abstract:Continuous treatment of high-loaded ammonia nitrogen wastewater was carried out by a self-made hybrid membrane bioreactor.When the ratio of influent COD/TN was in the range of 0.5~4.9,it was found that higher volumetric load of COD could produce higher removal efficiency of COD,ammonia nitrogen and total nitrogen. When the volumetric load of COD was more than 4.2 kg/(m~3·d),the average removal efficiency of COD,ammonia nitrogen and total nitrogen were more than(91.5)%,90.3% and 60.2% respectively.The ammonia nitrogen specific degradation rate from suspended activated sludge was 0.298 gNH_3-N/(gMLSS·d).As the pH of aerobic mixed liquor reduced 1,the concentration of ammonia nitrogen reduced 15 mg/L on average.Much nitrate and nitrite which kept the same trend could be found in the effluent,and the ratio of NO~-_2-N/NO~-_3-N was about 1.78.The results suggest that the removal of nitrogen by hybrid membrane bioreactor is achieved through short-cut nitrification and denitrification.