Abstract:A pilot-scale membrane bioreactor for biological nitrogen and phosphorus removal was utilized to treat the domestic sewage in a northern city.The operation for about 200 days shows that the removal rates of COD and BOD5 are 93% and 98% respectively,in which the contribution rates of biodegradation and membrane rejection to COD removal are 88.4% and 11.6% respectively.The sludge production is 0.2 kgVSS/kgCOD at the average loading rate of 0.68 kgCOD/(m3·d).Without addition of carbon source,ammonia nitrogen is totally nitrified,and the average removal rate of TN is about 79%,with the effluent TN of 10.76 mg/L.During the alternate domestication under anaerobic,anoxic and aerobic conditions,denitrifying PAOs and aerobic PAOs are enriched and enhanced.When the SRT is about 40 days,the average removal rate of TP is about 85%,with the effluent TP of 0.93 mg/L,in which the contribution rates of denitrifying PAOs,aerobic PAOs and membrane rejection to TP removal are 44.63%,51.84% and 3.53% respectively.Intermittent suction,on-line air bubble scouring,hydraulic backwash and regular chemical wash can effectively inhibit membrane fouling and control TMP at 20 to 30 kPa,which ensures the continuous operation of MBR.