Development of a High Resolution MFL Inspection System for Tank Floors

SONG Xiao-chun,HUANG Song-ling,ZHAO Wei,LI Jiu-chun,LI Yu-zhong,CHANG Lian-geng
DOI: https://doi.org/10.3969/j.issn.1000-3932.2007.01.018
2007-01-01
Abstract:According to the defect characteristics and the failure mechanisms,a high-resolution inspection system is developed to test the storage tank floor effectively based on the magnetic flux leakage(MFL) technique.The effects of the local saturation magnetization on the signal-noise-ratio of inspection signals are analyzed,and the difficulty in the floor MFL inspection is presented.Furthermore,the major measures to improve the electromagnetic compatibility of the system are studied.The inspection experiment and industrial application demonstrate that the system,which included the power supply module,magnetizer and inspection device,data acquisition and transmission module,control unit and data analysis software,can detect the flaws on the upper and undersurface quickly and has such advantages of high sensitivity,good reliability and easy operation.And some performance indexes of the apparatus like the defect location and sizing accuracy are able to meet the requirements of the API Std 653.
What problem does this paper attempt to address?