Study of the Minimum Refrigeration Temperature of Regenerative Cryocoolers

GM Chen,GB Chen,JP Yu
DOI: https://doi.org/10.1016/s0011-2275(97)00019-2
IF: 2.134
1997-01-01
Cryogenics
Abstract:Based on the principles of thermodynamics, the relation between the isentropic expansion coefficient μs and the isobaric specific heat Cp has been found. The values of μs at different temperatures and pressures are calculated. From theoretical and experimental values of Cp of helium in the supercritical area, the minimum refrigeration temperature which may be reached by traditional regenerative cryocoolers is theoretically demonstrated. It is pointed out that this boundary is just the lambda line of helium. In order to obtain temperatures lower than the lambda line, a new type of regenerative cryocooler which can work in the helium II region is proposed. The working principle, schematic diagram and theoretical refrigeration temperature of this new cryocooler are discussed.
What problem does this paper attempt to address?