Comparison of Mercury-free Microsensors Based on Gold Nanoparticles for Heavy Metals Detection

WANG Jin-Fen,BIAN Chao,TONG Jian-Hua,SUN Ji-Zhou,XIA Shan-Hong
DOI: https://doi.org/10.3724/SP.J.1096.2012.20470
IF: 1.193
2012-01-01
Chinese Journal of Analytical Chemistry
Abstract:This paper presents two kinds of mercury-free electrochemical microsensors for simultaneous detection of heavy metals, which are L-aspartic acid/L-cysteine/gold nanoparticles (Asp/Cys/GNPs/microelectrode chip) and Sn film/gold nanoparticles modified microelectrode chip (Sn/GNPs/microelectrode chip). Electrochemical analysis of metal ions on Asp/Cys/GNPs/microelectrode chip was investigated by square wave voltammetry under the optimized conditions. The microsensor exhibited wide linear range from 5 mu g/L to 2000 mu g/L for Cu2+ and Pb2+ ions, with limit of detection of 1 mu g/L. In situ tin film deposition was used in detection of heavy metals for the forming of alloy with heavy metals. Electrochemical analysis of metal ions on Sn/GNPs/microelectrode chip was investigated by square wave stripping voltammetry. The Sn/GNPs/microelectrode chip showed high sensitivity to Cu2+, Pb2+ and Zn2+ ions. This microsensor revealed good linear behavior in the examined concentration ranges from 5 to 500 mu g/L for Cu2+ and Pb2+, from 10 to 500 mu g/L for Zn2+, with a limit of detection of 2 mu g/L for Cu2+, 3 mu g/L for Pb2+ and 5 mu g/L for Zn2+. In addition, metal ions detection method using the two kinds of microsensor are green, simple, reused and compatible with the microfluid chip for on-site analysis.
What problem does this paper attempt to address?