In-situ Visualization of Hollow Fiber Membrane Fouling by Ultrasonic-Based Wavelet Technique

李建新,许新成,徐妮妮,张玉忠
DOI: https://doi.org/10.3969/j.issn.1007-8924.2010.02.001
2010-01-01
Abstract:Ultrasonic time-domain reflectometry(UTDR) and wavelet transform were employed to monitor the initial fouling in a single polyethersulfone hollow fiber membrane(inside diameter: 0.8 mm;outside diameter: 1.2 mm) during microfiltration of 2.4 g/L kaolin solution.Results showed that the hollow fiber structure and membrane fouling were visualized from the wavelet contour map.The membrane flux declined with the fouling process,whereas the echo durations of upside and underside walls of the hollow fiber lumen changed regularly in time-domain with the fouling process.These systematic changes are relevant to the surface deposition and growth of fouling layer on the fiber lumen.At 420 min of fouling operation,SEM observation revealed that the fouling layer deposited on the underside surface of the lumen was thicker than that on the upside surface,which corresponded well with the results obtained by ultrasonic measurements.