Effects of Duct Inclination Angle on Thermal Entrance Region of Laminar and Transition Mixed Convection

DaoTong Chong,JiPing Liu,JunJie Yan
DOI: https://doi.org/10.1016/j.ijheatmasstransfer.2007.12.010
IF: 5.2
2008-01-01
International Journal of Heat and Mass Transfer
Abstract:Experimental investigation was performed on the mixed convection heat transfer of thermal entrance region in an inclined rectangular duct for laminar and transition flow. Air flowed upwardly and downwardly with inclination angles from −90° to 90°. The duct was made of duralumin plate and heated with uniform heat flux axially. The experiment was designed for determining the effects of inclination angles on the heat transfer coefficients and friction factors at seven orientations (θ=−90°, −60°, −30°, 0°, 30°, 60° and 90°), six Reynolds numbers (Re≈420, 840, 1290, 1720, 2190 and 2630) within the range of Grashof numbers from 6.8×103 to 4.1×104. The optimum inclination angles that yielded the maximum heat transfer coefficients decreased from 30° to −30° with the increase of Reynolds numbers from 420 to 1720. The heat transfer coefficients first increased with inclination angles up to a maximum value and then decreased. With further increase in Reynolds numbers, the heat transfer coefficients were nearly independent of inclination angles. The friction factors decreased with the increase of inclination angles from −90° to 90° when Reynolds numbers ranged from 420 to 1290, and independent of inclination angles with higher Reynolds numbers.
What problem does this paper attempt to address?