Effect of Inflow Water C/N Ratios on Nitrogen and Phosphorus Removal in Continuous-Flow Double Sludge System

Zhu Wentao,Lü Xiwu,Shi Jing
DOI: https://doi.org/10.3969/j.issn.1009-0177.2012.01.011
2012-01-01
Abstract:The pollutants removal efficiencies and function mechanism of continuous flow double sludge system were explored under various C / N ratios through adding different carbon sources and adopting a simulated pilot test of sewage treatment.Results indicated that continuous flow double sludge system in different C / N ratios all can obtain stable nitrogen and phosphorus removal effect.Denitrification could be strengthen with C / N ratios rising,and the removal efficiency of TN would go up.The average removal efficiency of 86 % were obtained at the C / N ratios of 5 and 6.C / N ratios effected the removal of ammonia nitrogen less while it had a significant influence on TP removal efficiency.The removal rate of TP decreases gradually with increasing of C / N ratios.When the C / N ratio was 3,TP removal efficiency reached a peak,the highest for 93%,but the average removal rate only got 61 % under the ratio of 6.These results demonstrated that continuous flowing double sludge system had a better treatment effect for low C / N ratio sewage.
What problem does this paper attempt to address?