Study on the Affecting Factors of Continuous-flow Two-sludge System

LI Xiang-kun,JIANG An-xi,YU Jian,ZHANG Li-cheng,BAO Lin-lin,ZHANG Jie
DOI: https://doi.org/10.3969/j.issn.2095-1922.2005.05.032
2005-01-01
Abstract:The affecting factors of the continuous-flow two-sludge system for simultaneous biological phosphorus and nitrogen removal were investigated in order to decide on the best working state of the system.For this purpose the experiments of the affecting factors on the system including influent COD/TN ratio(C/N),bypass sludge flow ratio(BFR) and HRT of the post-aeration reactor(PA_(HRT)) were arranged.Long-term experiments showed that when C/N ranged between 3.8 and 6.0,the removal efficiency of TN,TP and COD were 83%,92% and 86% respectively,and the perfect C/N to the system was lying between 4 and 5.As to BFR,it was controlled between 3.3 and 3.8,and the lower it was,the better the removal efficiency could be reached.With BFR either higher than 4.8 or lower than 2.8,the removal efficiency decreased.Furthermore,PA_(HRT) should not be controlled longer than 60 minutes;if so,not only will the settling performance be destroyed but the proportion of denitrifying phosphorus removal bacteria(DPB) in phosphorus accumulating organism(PAO) will decrease,and the system can not operate under steady status.
What problem does this paper attempt to address?