Simulation and Experiments for the Q(Ext) of A Cavity Beam Position Monitor

Li Xiang,zheng Shu-Xin
DOI: https://doi.org/10.1088/1674-1137/34/3/020
IF: 2.944
2010-01-01
Chinese Physics C
Abstract:The external Q (Qext) of the dipole mode is a key parameter of the Cavity Beam Position Monitor (CBPM). It determines the amplitude and length of the dipole mode signal. In this paper, Qext of a CBPM whose waveguides were open to the air was simulated and measured, and the results agreed with each other. Then four waveguide-to-coaxial cable adpaters were adjusted and assembled to the CBPM, and Qext remained unchanged. This progress provides a reliable method to evaluate Qext in the physics design without simulating the structurally complex adapters.
What problem does this paper attempt to address?