Characteristics of Novel Bipolar Corona Discharger

杨振兴,向晓东,陈旺生
DOI: https://doi.org/10.13336/j.1003-6520.hve.2008.05.031
2008-01-01
Abstract:In order to find a corona discharger with better discharge parameters,and solve the problem of exiting corona discharger which can not generate corona on plate-electrode but only on high-voltage-electrode,A bipolar corona discharger is applied to generate positive and negative corona discharge by connecting with unipolar high voltage power supply,by contrast,existing corona dischargers can only generate unipolar corona.Voltage-current characteristics,discharging phenomenon and ionic wind of bipolar corona discharger are experimentally carried out.The positive and the negative ion wind velocities in core area are about 2m/s when the distance between the opposite electrodes is 100mm at the voltage of 3.4kV measured by a Particle Image Velocimetry(PIV).Compared with needle-to-plate corona discharger,bipolar corona discharger can generate higher current density and discharging power under a lower operating voltage.