Abstract:Objective:HPLC was used to determine the content of chlorogenic acid in Caulis stauntoniae cbinensis tablet.Methods:The study indicated that the effects of separation and determination were optimum when deter-mination parameters were as follows:analytic column:Shim-pack VP-ODS column,the mobile phase was acetonitrile-0.1% Phosphate (11:89),The flow rate was 1 ml/min;UV detectionwavelength was 327 nm.Results:The repressive equation had a good linear relationship (r=1.000 0).The relationship of injection amounts and peak was linear in the range of 10.21-102.1 μg/ml and recovery rate was 98.9%(RSD=0.8%).The method was simple and available,accuracy and good reproducibility.Conclusion:This Caulis stauntoniae cbinensis tablet determination of chlorogenic acid content,the results are stable,accurate and reliable,can be used as the variety of quality control methods.