Determination of Syringic Acid and Its Impurities by High Performance Liquid Chromatography
LI Jun,ZHOU Cai-xia,ZHOU Xiao-bo,HE Jian-she,HU Xian-ming
DOI: https://doi.org/10.3969/j.issn.1006-6144.2000.02.012
2000-01-01
Abstract:An HPLC method has been developed for the simultaneous determination of syringic acid and it's impurities [3,4,5 trimethoxybenzoic acid , 3,4,5 trihydroxybenzoic acid, 3,4 dihydroxy 5 methoxy benzoic acid]. The column used was ODS 3 (150 mm×4.0 mm i.d). The mobile phase was a mixture of methanol water 36% acetic acid (40∶60∶2, V/V/V ). The wavelength range of UV detection was 250nm~300nm. Under this chromatographic conditions, the components could be separated completely within 15 minutes. The linear relationship was good for the concentration range under investigation. The detection limits of syringic acid, 3,4,5 trimethoxybenzoic acid, 3,4,5 trihydroxybenzoic acid, 3,4 dihydroxy 5 methoxy benzoic acid were 1.40 ng, 1.10 ng, 0.90 ng and 1.70 ng, respectively. The proposed method was rapid, accurate and has be applied to the on line analysis of syringic acid.