Content Determination of Testosterone Propionate in Testosterone Propionate Paints by HPLC

DENG Daiquan,FENG Bimin,ZHANG Hao
DOI: https://doi.org/10.3969/j.issn.1001-0408.2006.03.024
2006-01-01
Abstract:OBJECTIVE:To establish a HPLC method for the content determination of testosterone propionate in testosterone propionate paints.METHODS:The assaying was conducted on a Kromasil C 18 column with methanol-water solution(80∶20)as mobile phase,the detection wavelength was254nm and the flow rate was1.0ml/min.RESULTS:The linear concentration range of the testosterone propionate was100~400mg/ml(r=0.9997)with average recovery rate at98.5%(RSD=0.55%).CONCLUSION:The method is simple,accurate and reproducible,and it can be used for the quality control of testosterone propionate paints.
What problem does this paper attempt to address?