Research on Subsurface Detection Using Magneto-optic Microscopy System

程玉华,周秀云,李平飞,廖百胜
2008-01-01
Abstract:Magneto-optic microscopy system(MOMS) is utilized to detect invisible and buried subsurface flaws in metallic specimens.The resolution of the magneto-optic images are always low because of the interference factors including the change of the sending light,the change of YIG's magnetic domain and some other noises.In this paper,according to the choice of the MO thin films,the design of the eddy current exciting device and the development of the image processing approaches,the factors which can affect the resolution are discussed and the correlative improving methods are introduced.Experimental tests have been done and the methods presented turn out to be reliable.