Corrosion behaviour of carbon steel in different concentrations of HCl solutions containing H2S at 90°C
Junwen Tang,Yawei Shao,Tao Zhang,Guozhe Meng,Fuhui Wang
DOI: https://doi.org/10.1016/j.corsci.2011.01.041
IF: 7.72
2011-01-01
Corrosion Science
Abstract:The corrosion behavior of SAE-1020 carbon steel in H 2 S-containing solutions with different concentration of HCl at 90 °C was investigated by weight loss, electrochemical measurements, SEM and XRD analysis. The results showed that the corrosion rate of carbon steel increased with increasing HCl concentration. Uniform corrosion was found on the carbon steel surface in H 2 S + HCl solutions, while corrosion cavities were observed in the solution only containing H 2 S. The ratio of Faradaic process of total corrosion process increased with the increase of HCl concentration. The corrosion products were solely composed of mackinawite in the H 2 S-containing solutions with or without HCl. Keywords A. Steel B. Weight loss B. EIS B. SEM B. XRD C. Acid corrosion 1 Introduction Petrochemical plants have suffered continuous economic loss and human casualties due to metallic materials corrosion in H 2 S-containing environments [1] . The salts and sulfide compounds dissolved in crude oil can provoke the formation of a corrosive aqueous solution whose chemical composition involves the presence of both hydrochloric acid (HCl) and hydrogen sulfide (H 2 S) [2,3] . This corrosion aqueous solution is very aggressive causing varied damages on carbon steel during plant operation in primary distillation plants. Several previous studies have been performed related to the corrosion process of iron and steel in H 2 S solutions [2,4–15] . These works studied the influence of H 2 S on the corrosion phenomena at ambient temperature. In H 2 S-containing solutions, the corrosion process of metal may be accompanied by the formation of sulfide film on the metal surface and leads to more complicated corrosion behavior [12] . Previous researches have shown that H 2 S had a remarkable acceleration effect on both the anodic iron dissolution and the cathodic evolution in most cases [6–9] , but H 2 S may exhibited an inhibitive effect on the corrosion of iron or steel weld while the lower H 2 S concentration (⩽0.04 mmol L −1 ), pH value of 3–5, and the longer immersion time (⩾2 h) are met simultaneously [7,8,12,13] . Recently, the influence of H 2 S concentration on the corrosion behavior of carbon steel at 90 °C has been investigated [16] . However, little research has been done on the corrosion behavior of carbon steel in the presence of H 2 S and HCl at the temperature of the condensation system in primary distillation plants, which usually is greater than 70 °C. Therefore, the purpose of the present work was to study the effect of HCl concentration on the corrosion behavior of SAE-1020 carbon steel in H 2 S-containing solutions at a typical temperature (90 °C) of the condensation system in CNPC primary distillation plants by means of weight loss method, electrochemical measurements, X-ray diffraction (XRD) and scanning electron microscopy (SEM). 2 Experiment 2.1 Experimental setup Experiments were conducted at atmospheric pressure in a glass cell ( Fig. 1 ) including a water bath in order to control temperature to 90 ± 1 °C. A typical three-electrode cell was used with a saturated calomel electrode (SCE) (GD-II, BRICEM, China) as the reference electrode, a large piece of platinum plate with a surface area of over 4 cm 2 as the counter electrode, and a SAE-1020 carbon steel specimen as the working electrode. Residual H 2 S was absorbed by gas absorbent. 2.2 Material and specimen preparation The material employed was SAE-1020 carbon steel, which has a composition of 0.20% C, 0.32% Si, 0.56% Mn, 0.033% P, 0.032% S and Fe as the balance. The specimens with an exposed surface of 10.0 × 10.0 mm 2 were machined from the carbon steel sheet and embedded in the epoxy resin. Only its cross-section contacted the electrolyte. Prior to each experiment, the exposed metal surface of each specimen was ground with wet silicon carbide paper to 1000 grade, degreased with acetone, cleansed with distilled water and dried in a compressed hot air flow. 2.3 Electrolyte solutions preparation Analytical reagent grade H 2 SO 4 , HCl, Na 2 SO 4 and Na 2 S were used directly without further purification. The 0.25 M Na 2 SO 4 , 0.5 M H 2 SO 4 and 0.5 M Na 2 S solutions were prepared in distilled water. Base solution (0.25 M Na 2 SO 4 ) containing 198.99 mg L −1 H 2 S were used as a common corrosion environment. The chemical composition of hydrogen sulfide solution was obtained based on the average concentration of H 2 S in the condensation system of CNPC primary distillation plants. The H 2 S-containing solutions with different concentration of HCl were prepared from the concentrated Na 2 S solution and the H 2 SO 4 solution and the analytical regent grade HCl in the following way: 1000 mL of the 0.25 M Na 2 SO 4 solution was filled in the glass cell at first, and then the suitable volume of Na 2 S solution and an equivalent volume of H 2 SO 4 solution were added into the Na 2 SO 4 solution, subsequently the suitable volume of concentrated hydrochloric acid (37 wt%) was added into above solution. Take the case of the preparation of the 198.99 mg L −1 H 2 S solution containing 0.010 wt% HCl, 25.43 ml of 0.5 M Na 2 S solution and the same volume of 0.5 M H 2 SO 4 solution were firstly added into 1000 ml Na 2 SO 4 solution, and then 0.25 ml of 37 wt% HCl was added to the solution. The pH value of the test solution was determined using a pH meter (PHSJ-4A, SPSIC, China). The precise concentration of H 2 S was determined by the iodometric titration method in triplicate to make sure the results were reproducible and reliable. Table 1 summarizes the different electrolyte solutions studied in the present work. 2.4 Electrochemical measurement Potentiodynamic polarization curves measurements were performed at a potential scan rate of 0.333 mV s −1 . The potential range was from −0.30 V to 0.30 V vs. open-circuit potential (OCP). All potentials reported in this paper were measured with respect to the SCE. The electrochemical impedance spectroscopies (EIS) were performed at OCP with a sinusoid signal of 5 mV amplitude and at frequencies ranging from 100 kHz to 10 MHz. The data were acquired in four cycles at each frequency, for providing good precision at all frequencies. The experimental data were analyzed using the commercial software ZsimpWin®. For better reproducibility, all above electrochemical experiments were repeated more than three times and were carried out using IviumStat Electrochemical Interface (Ivium Technologies, Netherlands) controlled by PC. 2.5 Weight loss experiment Specimens were cut into 10.0 × 10.0 × 2.5 mm for weight loss tests and three specimens used for each series were measured for good reproducibility. The samples were weighed before exposure by means of a digital balance (Sartorius CP225D) with a precision of 0.00001 g for the original weight ( W 0 ). After immersion for 1 h in test solutions with a bath at 90 ± 1 °C, the corroded specimens were taken out from the solutions, and cleaned with distilled water. The corrosion products on carbon steel surface were removed using the chemical products-cleanup method [17] . Finally, the samples were weighed again in order to obtain the final weight ( W 1 ). The corrosion rate ( CR ) (g m −2 h −1 ) was calculated with Eq. (1) . (1) CR = W 0 - W 1 A × t where W 0 (g) and W 1 (g) are the original weight and final weight of specimens, respectively, A (m 2 ) is the exposed surface area of specimens, and t (h) represents the immersion time. 2.6 Surface morphology observation and corrosion products analysis The corrosion morphology of carbon steel was characterized by a digital camera (SONY W170) and SEM (Cambridge S240). Corrosion products on the corroded samples were analyzed using X′ Pert Pro X-ray diffractometer with a Cu Kα X-ray source to determine the phases. To observe the corrosion morphology under the corrosion products, the corrosion products were removed using the chemical products-cleanup method [17] . 3 Results 3.1 Corrosion rates of carbon steel Weight loss measurements can provide the most reliable results concerning the corrosion rates ( CR ) of carbon steel, so that the corresponding corrosion data obtained from them approach service conditions are more accurately than that obtained with any other test [18,19] . The average corrosion rates of carbon steel in the H 2 S solutions with and without HCl obtained from weight loss tests are shown in Fig. 2 . Corrosion rates of carbon steel increased significantly with increasing HCl concentration. The corrosion rate increased up to 17.31 g m −2 h −1 in the solution with 0.100 wt% HCl, which was 2-fold greater than that of carbon steel in HCl-free solution (8.30 g m −2 h −1 ). The results indicated that the HCl concentration had a strong influence on the corrosion resistance of the carbon steel and the carbon steel showed a greater activity for higher HCl concentrations. 3.2 Potentiodynamic polarization curves The potentiodynamic polarization curves for carbon steel in the H 2 S-containing solutions in absence and presence of different HCl concentrations at 90 °C are shown in Fig. 3 . A typical feature of these polarization curves was that the hydrogen evolution reaction (cathodic curve) was remarkably accelerated by increasing HCl concentration. However, the anodic curves obtained showed very similar current densities, regardless of the HCl concentration. As can be seen in Fig. 3 , the anodic process of carbon steel exhibited the anodic iron dissolution. This could be due to the fact that the corrosion process involved formation and dissolution of corrosion products, always maintaining the surface active [4] . Therefore, the fact that the anodic current densities were not modified in the H 2 S-containing solutions with various HCl concentrations was possibly attributed to metal dissolution [20–22] . However, the cathodic process of carbon steel was more complicated and remarkably depended on the concentration of HCl. The determination of corrosion parameters ( E corr , R p , b a , b c , and i corr ) could provide more information about the overall corrosion process. Jankowski and Juchniewicz [23] proposed a four-point method for determining the corrosion rate as a simple and accurate method. In this method, four current density values at four applied potentials, E = Δ E , - Δ E , 2 Δ E , and - 2 Δ E , on a polarization curve are used to determine the corrosion current density ( i corr ) and the harmonic mean of the Tafel constants ( B ) and of each Tafel constant ( b a and b c ). The i corr and b a and b c are determined from the following equations [23,24] : (2) i corr = I 1 I - 1 I 2 I - 2 - 4 I 1 I - 1 (3) B = b a b c 2.3 ( b a + b c ) = Δ E cosh - 1 I 2 I - 2 2 I 1 I - 1 - 1 (4) b a = Δ E log { I 1 / i corr [ 1 - exp ( Δ E / B ) ] } (5) b c = 2.3 b a B b a - 2.3 B where I 1 , I −1 , I 2 , and I −2 are the current densities at the four overpotentials, Δ E , - Δ E , 2 Δ E , and - 2 Δ E . These equations from the Bulter–Volmer equation that is valid in the potential range where reactions are controlled by activation process [24] . Additionally, according to Stern and Geary [25] , the polarization resistance ( R p ) can be expressed as: (6) R p = B i corr The corrosion parameters for the carbon steel were determined by the analysis software of IviumStat Electrochemical Interface with the four-point method. Table 2 summarizes the corrosion potentials ( E corr ), Tafel slopes ( b a and b c represent anodic and cathodic, respectively) and corrosion currents ( i corr ) and their standard deviation as well as the calculated values of polarization resistances ( R p ). The corrosion potential shifted towards positive direction with increasing HCl concentration and the phenomenon seemed to be more remarkably in the solutions with high concentration of HCl. For example, the corrosion potential of carbon steel in the solution containing 0.100 wt% HCl was close to −0.57 V SCE , which was 100 mV more positive than that measured in the HCl-free solution. It is well known that the corrosion potential is the result of the two competitive reactions of the cathodic and anodic process [26,27] . In this work, the anodic current densities were not modified in the H 2 S-containing solutions with various HCl concentrations, so the cathodic hydrogen evolution process of metal surface was promoted with increasing HCl concentration, which contributed to the positive shift of the corrosion potential. Anodic Tafel slops, b a ( Table 2 ), in all solutions were very similar (about 0.08 V per decade), regardless of the concentration of HCl in the H 2 S solutions. This behavior indicated that the concentration of HCl contributed similarly to the anodic process. However, the slopes of cathodic branch, b c , ( Table 2 ) were considerably dependent on the concentration of HCl. This fact, along with greater values of these slopes compared with those from the anodic branch, indicated the complex nature of the reduction process [4] . Additionally, the corrosion current density ( i corr ) increased from 0.188 mA cm −2 to 1.49 mA cm −2 and the polarization resistance R p values decreased with increasing HCl concentration in the solutions ( Table 2 ). The results implied that the cathodic process was controlled by the concentration of HCl in the solutions, and the corrosion resistance of carbon steel was obviously deteriorated with increasing concentration of HCl from 0 wt% to 0.100 wt%. 3.3 Electrochemical impedance spectroscopy Fig. 4 shows the Nyquist diagrams obtained for carbon steel in the H 2 S-containing solutions with various concentration of HCl at the open-circuit potential (OCP). The shape and the diameter of these experimental impedance circles depended on the concentration of HCl. The impedance diagrams obtained in the solutions without and with different HCl concentrations (0.005, 0.010, 0.025, and 0.050 (in wt%)) revealed two well-separated capacitive loops, including a high frequency (HF) depressed capacitive loop and a low frequency (LF) capacitive loop. However, the diagram measured in the 0.100 wt% HCl solution seemed to make up of three semicircles with two capacitive loops and an inductive loop. According to the measured EIS spectra in Fig. 4 , it can be seen that the diameter of the circle of the high frequency loop decreased with increasing concentration of HCl. It was determined that the diameter was about 35 Ω cm 2 in the H 2 S solution without HCl, which was almost 5-fold greater than that of carbon steel in the 0.100 wt% HCl solution (about 7 Ω cm 2 ). This indicated that the corrosion resistance of carbon steel deteriorated with increasing HCl concentration, which was in good agreement with the results of the weight loss test ( Fig. 2 ) and the potentiodynamic polarization curves ( Fig. 3 ). At the same time, the Nyquist plot measured in the 0.010 wt% HCl solution exhibited a high frequency capacitive loop whose top frequency (5.62 Hz) was greater than that of the capacitive loop (2.37 Hz) obtained in the H 2 S solution with 0.005 wt% HCl or without HCl. The top frequency of a high frequency capacitive loop remarkably increased as HCl concentration increased above 0.025 wt%, up to 0.100 wt% ( Fig. 4 b), which also indicated that the carbon steel was corroded more easily in the stronger acidic solutions [7] . 3.4 Effect of H 2 S and HCl on the corrosion product and corrosion morphology Fig. 5 shows the X-ray diffractograms of the corrosion products on the surface of carbon steel in H 2 S-containing solution without and with 0.010 wt% HCl at 90 °C, respectively. It was determined that the corrosion products just consisted of mackinawite in both of the above cases, indicating that hydrochloric acid had not influence on the composition of corrosion products in H 2 S-containing solutions. In general, the corrosion products on carbon steel surface are non-stoichiometric iron sulfide films mainly composed of mackinawite and pyrrhotite in environment containing H 2 S [2,28–42] . Berner [40,43] and Rickard [44] have observed that mackinawite is typically the sole crystalline product of precipitation of ferrous ions by H 2 S or its salts below 100 °C in the absence of oxidants. However, the protective property of iron sulfide film depends on the H 2 S concentration, pH of solution and immersion time of electrode [8] . The solubility of iron sulfide increased with decreasing pH value or increasing the HCl concentration. At the pH values of 3–5, H 2 S begins to exhibit its inhibiting effect as FeSH + species can form partially mackinawite [8] . Shoesmith et al. [45] studied the corrosion of iron in a deaerated H 2 S-saturated solution and found that metal dissolution predominated and very little iron sulfide was formed at the lower pH values (1.7 and 2.7). The macroscopical corrosion morphology of carbon steel surface after 1 h immersion in the H 2 S-containing solutions with different HCl concentration at 90 °C is shown in Fig. 6 . The black corrosion products formed on the steel surface in the H 2 S-containing solutions without HCl ( Fig. 6 a) or with low HCl concentration (0.005 wt% and 0.010 wt%) ( Fig. 6 b and c) could be observed. With the increase of HCl concentration, the region of carbon steel surface covered with the black corrosion products decreased obviously ( Fig. 6 d–f). The pH value decreased with increasing the HCl concentration and the iron sulfide not easily deposited on the steel surface. At the lower pH values metal dissolution predominated and little iron sulfide formed due to the relatively greater solubility of iron sulfide phases [8,13] . SEM micrographs of carbon steel after 1 h immersion in H 2 S-containing solutions with different concentration of HCl are shown in Fig. 7 . The carbon steel surface was greatly corroded in all solutions. After removing the corrosion products, the corrosion cavities were observed on the carbon steel in the H 2 S-containing solution without HCl ( Fig. 7 b). However, when HCl was added into the H 2 S-containing solutions, the corrosion cavities on the carbon steel surface disappeared and the uniform corrosion appeared. Additionally, the granular substances appeared on the surface of carbon steel were also observed ( Fig. 7 d, f, h, k, and n). 4 Discussion 4.1 Effect of HCl on the corrosion of non-Faradaic process From optical micrograph of SAE-1020 carbon steel ( Fig. 8 ), the phases of carbon steel mainly consisted of ferrite (F), and carbides (Fe 3 C) deposited in the grain boundary especially in the tri-angle grain boundary [16] . The corrosion processes of carbon steel in H 2 S-containing solutions consisted of two simultaneous processes: grain dissolution process and micro-galvanic corrosion process [16] . Severe corrosion cavities on the carbon steel surface in the H 2 S-containing solution due to cementites stripping off from the grain boundary, which is the potential-independent “chemical dissolution” process or the non-Faradaic process. However, with the addition of HCl in the H 2 S-containing solution, the grain dissolution process was promoted by the addition of HCl, the cementite was not easily stripped off and the uniform corrosion appeared on the carbon steel surface ( Fig. 7 d, f, h, k, and n). i corrweight of the weight loss method reflected the total corrosion rate, including Faradaic process and non-Faradaic process. However, i corrTafel of the potentiodynamic polarization method just reflected the corrosion rate of Faradaic process. Ratio in Eq. (7) can reflect the influence of non-Faradaic process on the total corrosion rate ( Fig. 9 ). (7) Ratio ( % ) = i corrweight - i corrTafel i corrweight × 100 From Fig. 9 , in the H 2 S-containing without HCl, Ratio is 76%, which meant that non-Faradaic process was the dominant process. That is to say, the process of cementites stripped off from the grain boundary was the dominant process. From Fig. 7 b, the corrosion cavities formed on the surface of carbon steel due to cementites stripping off from the grain boundary [16] . With the addition of HCl, Ratios were decreased. When HCl concentration increased to 0.025 wt%, it could be found that Ratio was 49.2%. HCl concentration increased to 0.100 wt%, Ratio was 4.6%, which meant that the corrosion process mainly obeyed Faraday’s law and non-Faradaic process became weak. From Fig. 7 d, f, h, k, and n, the uniform corrosion appeared and no corrosion cavities. Therefore, HCl in the H 2 S-containing solution could increase the ratio of Faradaic process of total corrosion process. 4.2 Mechanism of formation and dissolution of the corrosion products Based on the previous researches [6–9,16] and the above results of EIS ( Fig. 4 ), XRD ( Fig. 5 ), and corrosion morphology ( Fig. 6 ), a probable mechanism of formation and dissolution mechanism of mackinawite as corrosion products in the H 2 S-containing solutions with different HCl concentrations could be described as follows [8,16,46] : (8) Fe + H 2 S + H 2 O → FeSH ads - + H 3 O + and / or Fe + HS - → FeSH ads - (9) FeSH ads - ⇌ k - 1 k + 1 FeSH ads + + 2 e - where the subscript ‘ads’ represents the adsorption on surface of carbon steel. The species FeSH ads + on the electrode surface could be incorporated directly into a layer of mackinawite via the following reaction [45] : (10) FeSH ads + → k 2 FeS 1 - x + x SH - + ( 1 - x ) H + or it could be hydrolyzed to yield Fe 2+ via Eq. (11) [8] . (11) FeSH ads + + H 3 O + → Fe 2 + + H 2 S + H 2 O H 2 S exhibited the different role on anodic process of carbon steel depending on the pH value in the solutions. When the HCl was absent or its concentration was low (0.005 wt% HCl), the pH value of the H 2 S-containing solution was about 3.03–3.31, the local supersaturation of FeS 1− x could be formed on the carbon steel surface via the reaction (10) , then nucleation and growth of one or more of the iron sulfide, mackinawite. The pH value (⩽2.75) of the H 2 S-containing solution decreased as the HCl concentration increased above 0.010 wt% and up to 0.100 wt%, iron dissolved by the reaction (11) and little iron sulfide formed on the electrode surface due to the relatively greater solubility of the sulfide solid. The precipitation of sulfide could dissolve directly, and the cathodic reaction occurred at cementite became weak. So the corrosion cavities on the carbon steel surface disappeared. Moreover, it was noted that the protective ability of mackinawite was worse than that of troilite [8] . Consequently, even if at lower HCl concentration and pH range of 3.03–3.31, the iron sulfide film had not any protection against corrosion of carbon steel. 4.3 Analysis of the shape of EIS data From simply fitting of EIS data, the values of the capacitance associated with the high frequency capacitive loop is about 10 −3 Ω −1 cm −2 s n . This is a greater value comparing with the conventional fitting data. Is it a reasonable data? We think that the present experiment was done at 90 °C, the results probably was different with the results presented in other researches at ambient temperature. Moreover, according to Yin et al. [46] and Li et al. [47] , the capacitance of electrical double layer is around 10 −2 Ω −1 cm −2 s n . So the results of EIS measurement in the present work are reasonable. Furthermore, the classical EIS theory is based on the measurement of static state. In this work, the corrosion process of iron or carbon steel in H 2 S-containing solutions is in the static state, although its corrosion rate is high. Hence, the classical EIS theory introduced by Cao [48] is suitable to interpret the impedance results. Cao [48] believed that if diffusion was not involved in the Faradic process for reaction sequence, the admittance Y (or impedance Z ) for the electrode could be expressed as: 1 / Z = Y = j ω C dl + Y F If the electrode reaction was controlled by one surface state variable X , then the faradic admittance Y F could be described as [48] : Y F = 1 / R t + ( ∂ I F / ∂ X ) ss ( ∂ X ′ / ∂ E ) ss / ( j ω - ∂ X ′ / ∂ X ) Correspondingly Y = j ω C dl + 1 / R t + ( ∂ I F / ∂ X ) ss ( ∂ X ′ / ∂ E ) ss / ( j ω - ∂ X ′ / ∂ X ) There was a capacitive loop in the high frequency range due to the double layer capacitance, C dl . There was a capacitive loop in the low frequency range caused by the Faradic electrochemical reaction process when ( ∂ I F / ∂ X ) ss ( ∂ X ’ / ∂ E ) ss < 0 . In contrast, there was an inductive loop in the low frequency range when ( ∂ I F / ∂ X ) ss ( ∂ X ′ / ∂ E ) ss > 0 . Let θ 1 and C FeSH ads - be the fraction of the surface coverage of the adsorbed intermediate FeSH ads + and the concentration of FeSH ads - in the H 2 S-containing solutions, respectively, then the rates of the reactions (9) and (10) can be expressed as: I + 1 = k + 1 ′ exp ( 1 - α 1 ) F RT E C FeSH ads - ( 1 - θ 1 ) = k + 1 C FeSH ads - ( 1 - θ 1 ) I - 1 = k - 1 ′ exp - α 1 F RT E θ 1 = k - 1 θ 1 v 2 = k 2 θ 1 I 1 = I + 1 - I - 1 = k + 1 C FeSH ads - ( 1 - θ 1 ) - k - 1 θ 1 where k +1 and k −1 are the formal rate constants of the forward and backward electrochemical reaction (9) , respectively; α 1 is the charge-transfer coefficient in reduction, which is assumed to be within 0 and 1 and independent of the electrode potential; F is the Faraday constant, E is the electrode potential, T is absolute temperature, and R = 8.314 J K −1 mol −1 . The state variable besides E is θ 1 in the present case, and then the rate of the increase of θ 1 can be expressed as: Ξ 1 = d θ 1 dt = K 1 I 1 - v 2 = K 1 k + 1 C FeSH ads - ( 1 - θ 1 ) - k - 1 θ 1 - k 2 θ 1 K 1 is the coverage-electricity conversion coefficient. ∂ Ξ 1 ∂ θ 1 ss = - K 1 k + 1 C FeSH ads - + k - 1 + k 2 < 0 where the subscript ‘ss’ denotes steady-state. The stability condition is fulfilled [48] . So the variable b can be calculated as: b = ∂ Ξ 1 ∂ E ss = K 1 ∂ I + 1 ∂ E ss - ∂ I - 1 ∂ E ss = K 1 F RT [ ( 1 - α 1 ) I + 1 + α 1 I - 1 ] > 0 The Faradic current density is I F = I 1 = I + 1 - I - 1 thus m = ∂ I F ∂ θ 1 ss = k + 1 C FeSH ads - + k - 1 < 0 and mb < 0 According to the theory of Cao [48] , when mb < 0, the impedance plane display will exhibit a capacitive loop at low frequencies. Additionally, it was believed that hydrogen evolution is the most dominant cathodic reaction at a given H 2 S concentration of the acidic solutions. When hydrogen ions diffuse through the diffusion boundary layer to the metal surface, hydrogen evolution involving an intermediate adsorbed hydrogen atom take place according to the following reactions: (12) H + + e - ⇌ k - 3 k + 3 H ads (13) H ads + H ads → k 4 H 2 where the rate constants of the unit reactions are k +3 , k −3 , and k 4 . If the fraction of the surface coverage of the adsorbed intermediate H ads is θ 2 , the rates of the reactions can be expressed as: I + 3 = k + 3 ′ exp - α 2 F RT E C H + ( 1 - θ 2 ) = k + 3 C H + ( 1 - θ 2 ) I - 3 = k - 3 ′ exp ( 1 - α 2 ) F RT E θ 2 = k - 3 θ 2 v 4 = k 4 θ 2 2 I 3 = I + 3 - I - 3 where I +3 and I −3 are the current densities of the forward and backward reaction (12) , respectively; C H + is the concentration of H + in solution nearby the surface of the electrode; k +3 and k −3 are the formal rate constants. α 2 is the charge-transfer coefficient in reduction. α 2 is assumed to be within 0 and 1 and independent of the electrode potential; F is the Faraday constant, E is the electrode potential, T is absolute temperature, and R = 8.314 J K −1 mol −1 . The effect of the diffusion H + is assumed to be ignored and the only state variable other than E is θ 2 in the presence case and the rate of the increase of θ 2 can be expressed as: Ξ 2 = d θ 2 dt = K 2 I 3 - v 4 = K 2 [ k + 3 C H + ( 1 - θ 2 ) - k - 3 θ 2 ] - k 4 θ 2 2 where K 2 is the coverage-electricity conversion coefficient. ∂ Ξ 2 ∂ θ 2 ss = - [ K 2 ( k + 3 C H + + k - 3 ) + 2 k 4 θ 2 ] < 0 Therefore, the stability condition is fulfilled. And then the variable b can be calculated as following: b = ∂ Ξ 2 ∂ E ss = K 2 ∂ I + 3 ∂ E ss - ∂ I - 3 ∂ E ss = - K 2 F RT α 2 I + 3 + ( 1 - α 2 ) I - 3 < 0 The Faradic current density is I F = I 3 = I + 3 - I - 3 thus m = ∂ I F ∂ θ 2 ss = - ( k + 3 C H + + k - 3 ) < 0 and mb > 0 which indicated that Nyquist plot should contain an inductive loop related to the surface state variable of adsorbed hydrogen ( θ 2 ) [48] . From the above theoretical calculation, the impedance diagram of anodic reaction, SAE-1020 carbon steel was corroded in H 2 S-containing solutions without HCl and with HCl, exhibited a capacitive loop at low frequencies; the impedance diagram of cathodic reaction, hydrogen evolution, exhibited an inductive loop. With the increase of HCl concentration, more hydrogen atoms might be absorbed on the carbon steel surface, the characteristic inductive loop will became more obvious. While HCl concentration increased to 0.100 wt% the characteristic inductive loop in the middle frequency appeared ( Fig. 4 b and c). 5 Conclusion The corrosion rate of SAE-1020 carbon steel at 90 °C increased with increasing the HCl concentration. HCl played a acceleration role on the cathodic hydrogen evolution and decreased the impedance modulus with the increase of HCl concentration from 0.005 wt% to 0.100 wt% in the H 2 S-containing solutions. The corrosion products, mackinawite, were not easily formed on the carbon steel surface due to the relatively greater solubility of the iron sulfide with increasing HCl concentration. The corrosion processes of carbon steel in H 2 S-containing solutions consisted of Faradaic process and non-Faradaic process. HCl in the H 2 S-containing solution could increase the ratio of Faradaic process of total corrosion process. Uniform corrosion was found on the carbon steel surface in H 2 S solutions with various concentration of HCl, while severe localized corrosion was observed in the solution only containing H 2 S which may be attributed to cementites stripped off from the grain boundary. Acknowledgments The authors acknowledge support of the academe of Lanzhou Petrochemical Company, CNPC, the program for New Century Excellent Talents in University of China (NCET-09-0052), the Fundamental Research Funds for the Central Universities (HEUCFZ1019). References [1] R. Cabrera-Sierra E. Sosa M.T. Oropeza I. Gonzalez Electrochemical study on carbon steel corrosion process in alkaline sour media Electrochim. Acta 47 2002 2149 2158 [2] H. Vedage T.A. Ramanarayanan J.D. Mumford S.N. Smith Electrochemical growth of iron sulfide films in H 2 S-saturated chloride media Corrosion 49 2 1993 114 121 [3] Z.A. Foroulis Role of solution pH on wet H 2 S cracking in hydrocarbon production Corros. Prev. Control 8 1993 84 89 [4] M.A. Veloz I. González Electrochemical study of carbon steel corrosion in buffered acetic acid solutions with chlorides and H 2 S Electrochim. Acta 48 2002 135 144 [5] S. Aezola J. Genesca The effect of H 2 S concentration on the corrosion behaviour of API 5L X-70 steel J. Solid State Electrochem. 8 2005 197 200 [6] H.Y. Ma X.L. Cheng S.H. Chen G.Q. Li X. Chen S.B. Lei H.Q. Yang Theoretical interpretation on impedance spectra for anodic iron dissolution in acidic solutions containing hydrogen sulfide Corrosion 54 1998 634 640 [7] H. Ma X. Cheng S. Chen C. Wang J. Zhang H. Yang An ac impedance study of the anodic dissolution of iron in sulfuric acid solutions containing hydrogen sulfide J. Electroanal. Chem. 451 1998 11 17 [8] H. Ma X. Cheng G. Li S. Chen Z. Quan S. Zhao L. Niu The influence of hydrogen sulfide on corrosion of iron under different conditions Corros. Sci. 42 2000 1669 1683 [9] X.L. Cheng H.Y. Ma J.P. Zhang X. Chen S.H. Chen H.Q. Yang Corrosion of iron in acid solutions with hydrogen sulfide Corrosion 54 1998 369 376 [10] Y.S. Choi J.G. Kim Aqueous corrosion behaviour of weathering steel and carbon steel in acid-chloride environments Corrosion 56 2000 1202 1210 [11] H.H. Huang W.T. Tsai J.T. Lee Cracking characteristics of A516 steel weldment in H 2 S containing environments Mater. Sci. Eng. A 188 1994 219 227 [12] H.H. Huang J.T. Lee W.T. Tsai Effect of H 2 S on the electrochemical behaviour of steel weld in acidic chloride solutions Mater. Chem. Phys. 58 1999 177 181 [13] H.H. Huang W.T. Tsai J.T. Lee Electrochemical behaviour of the simulated heat-affected zone of A516 carbon steel in H 2 S solution Electrochim. Acta 41 1996 1191 1199 [14] H.H. Rehan S.A. Salih H. El-Daley A.G. Gad-Allah Effect of sulfide ions on the corrosion behaviour of mild steel in acetate buffer Collect. Czech. Chem. Commun. 58 1993 547 [15] L. Quej-Aké R. Cabrera-Sierra E. Arce-Estrada J. Marín-Cruz EIS evaluation of the effect of neutralizing and inhibitor compounds on corrosion process of 1018 carbon steel in acid solutions typical of atmospheric distillation plants Int. J. Electrochem. Sci. 3 2008 56 66 [16] J. Tang Y. Shao J. Guo T. Zhang G. Meng F. Wang The effect of H 2 S concentration on the corrosion behaviour of carbon steel at 90 °C Corros. Sci. 52 2010 2050 2058 [17] Corrosion of metals and alloys—removal of corrosion products from corrosion test specimens, GB/T 16545-1996, idt ISO 8407, 1991. [18] E. Poorqasemi O. Abootalebi M. Peikari F. Haqdar Investigating accuracy of the Tafel extrapolation method in HCl solutions Corros. Sci. 51 2009 1043 1054 [19] Mohammed A. Amin Sayed S. Abd E.E.F. El-Rehim Rady S. El-Sherbini The inhibition of low carbon steel corrosion in hydrochloric acid solutions by succinic acid: Part I. Weight loss, polarization, EIS, PZC, EDX and SEM studies Electrochim. Acta 52 2007 3588 3600 [20] J.O’M. Bockris D. Drazic R. Despic The electrode kinetics of the deposition and dissolution of iron Electrochim. Acta 4 1961 325 [21] E.J. Kelly The active iron electrode J. Electrochem. Soc. 112 1965 124 [22] E. McCafferty N. Hackerman Kinetics of iron corrosion in concentrated acidic chloride solutions J. Electrochem. Soc. 119 1972 999 [23] J. Jankowski R. Juchniewicz A four-point method for corrosion rate determination Corros. Sci. 20 1980 841 851 [24] Y. Yi H. Kim Y. Park J. Kim Effect of an inhibitor on the stress corrosion cracking behaviour of alloy 600 in a high-temperature caustic solution Corrosion 61 2005 403 410 [25] M. Stern A.L. Geary Electrochemical polarization: I. A theoretical analysis of the shape of polarization curves J. Electrochem. Soc. 104 1957 56 63 [26] J. Liu Y. Lin X. Yong X. Li Study of cavitation corrosion behaviours and mechanism of carbon steel in neutral sodium chloride aqueous solution Corrosion 61 2005 1061 1069 [27] M.L. Doche J.Y. Hihn A. Mandroyan R. Viennet F. Touyeras Influence of ultrasound power and frequency upon corrosion kinetics of zinc in saline media Ultrason. Sonochem. 10 2003 357 362 [28] E. Sosa R. Cabrera-Sierra M.E. Rincoon M.T. Oropeza I. Gonzaalez Evolution of non-stoichiometric iron sulfide film formed by electrochemical oxidation of carbon steel in alkaline sour environment Electrochim. Acta 47 2002 1179 1208 [29] R.C. Newman K. Rumash J. Webster The effect of pre-corrosion on the corrosion rate of steel in neutral solutions containing sulphide: relevance to microbially influenced corrosion Corros. Sci. 33 1992 1877 [30] S. Tsujikawa A. Miyasaka M. Veda S. Ando T. Yamada Alternative for evaluating sour gas resistance of low-alloy steels and corrosion-resistant alloys Corrosion 49 1993 409 419 [31] T. Hemmingsen H. Lima Electrochemical and optical studies of sulphide film formation on carbon steel Electrochim. Acta 43 1998 35 40 [32] H.T. Param B.C. Allan Dissolution of iron during the initial corrosion of carbon steel in aqueous H 2 S solutions Can. J. Chem. 57 1979 188 196 [33] A.G. Wikjord T.E. Rummery F.E. Doern D.G. Owen Corrosion and deposition during the exposure of carbon steel to hydrogen sulfide water solutions Corros. Sci. 20 1980 651 [34] F.H. Meyer O.L. Riggs R.L. McGlasson J.D. Sudbury Corrosion products of mild steel in hydrogen sulfide environments Corrosion 14 1958 109 115 [35] H.T. Param B.C. Allan Dissolution of iron sulfide (troilite) in aqueous sulfuric acid J. Phys. Chem. 80 1976 1844 1848 [36] B.G. Pound G.A. Wright R.M. Sharp The anodic behaviour of iron in hydrogen sulfide solutions Corrosion 45 1989 386 392 [37] C. Milton Kansite = mackinawite FeS Corrosion 22 1966 191 193 [38] B.G. Pound R.M. Sharp G.A. Wright The corrosion of carbon steel and stainless steels in simulated geothermal media Aust. J. Chem. 38 1985 1133 1140 [39] R.A. Berner Tetragonal iron sulfide Science 137 1962 669 [40] R.A. Berner Thermodynamic stability of sedimentary iron sulfides Am. J. Sci. 265 1967 773 785 [41] R.H. Hausler L.A. Goeller R.P. Zimmerman R.H. Rosenwald Contribution to the “filming amine” theory: an interpretation of experimental results Corrosion 28 1972 7 16 [42] P. Taylor The stereochemistry of iron sulfides—a structural ration for the crystallization of some metastable phases from aqueous solution Am. Mineral. 65 1980 1026 [43] R.A. Berner Iron sulfides formed from aqueous solution at low temperatures and atmospheric pressure J. Geol. 72 1964 293 306 [44] D.T. Rickard The chemistry of iron sulphide formation at low temperatures Stockholm Contrib. Geol. 20 1969 67 95 [45] D.W. Shoesmith P. Taylor M.G. Bailey D.G. Owen The formation of ferrous monosulfide polymorphs during the corrosion of iron by aqueous hydrogen sulfide at 21 °C J. Electrochem. Soc. 127 1980 1007 1015 [46] Z.F. Yin W.Z. Zhao Z.Q. Bai Y.R. Feng W.J. Zhou Corrosion behaviour of SM 80SS tube steel in stimulant solution containing H 2 S and CO 2 Electrochim. Acta 53 2008 3690 3700 [47] J.B. Li X. Hou M.S. Zheng J.W. Zhu Joint effect of temperature, stress states and sulfur ions on the CO 2 corrosion behavior of N80 tubing steel Int. J. Electrochem. Sci. 2 2007 607 617 [48] C. Cao On the impedance plane display for irreversible electrode reactions based on the stability conditions of the steady-state: I. One state variable besides electrode potential Electrochim. Acta 35 1990 831 836
What problem does this paper attempt to address?
-
Corrosion behavior of carbon steel in H 2S-HCL-H 2O at 90 °C: II -the effect of HCl concentration on corrosion behavior of carbon steel in H 2S solutions
Junwen Tang,Yawei Shao,Zhen Chen,Xiqing Zhang,Guozhe Meng,Fuhui Wang
2011-01-01
Abstract:The electrochemical behavior of SAE-1020 carbon steel in acidic simulation solutions containing H 2S with different concentrations of HCl at 90 °C was investigated by mass loss method, electrochemical measurements, SEM observations and XRD. The results indicated that the cathodic depolarization was promoted greatly and the corrosion rate of carbon steel increased remarkably with the increase of HCl concentration in H 2S-containing solutions. Large numbers of corrosion holes formed on carbon steel in H 2S-containing solution without HCl, whereas only the uniform corrosion characteristic was observed on carbon steel surface in the simulation solutions containing different concentrations of HCl. Mackinawite was the sole corrosion product formed on the carbon steel surface in the H 2S-containing solutions with and without HCl.
-
Corrosion behavior of carbon steel in H 2S-HCl-H 2O at 90 °C: I -the effect of H 2S concentration on the corrosion behavior of carbon steel
Junwen Tang,Yawei Shao,Jinbiao Guo,Xiqing Zhang,Guozhe Meng,Fuhui Wang
2011-01-01
Abstract:The electrochemical behavior of low carbon steel in acidic simulation solutions containing different concentrations of H 2S at 90 °C was investigated by mass loss method, electrochemical measurements and observations of scanning electron microscope (SEM) and X-ray radiation diffaction (XRD). The results showed that the cathodic depolarization was enhanced greatly and the corrosion rate of carbon steel increased remarkably with the increase of H 2S concentration. The severe corrosion holes were observed on the carbon steel surface in the H 2S-containing solutions. The corrosion products layer deposited on carbon steel were mainly composed of mackinawite, which became loose, easily cracked and sloughed off with increasing concentration of H 2S.
-
CORROSION BEHAVIOR OF CARBON STEEL IN H2S-HCL-H2O AT 90℃ II-The Effect of HCl Concentration on Corrosion Behavior of Carbon Steel in H2S Solutions
TANG Junwen,SHAO Yawei,GUO Jinbiao,ZHANG Tao,MENG Guozhe,WANG Fuhui
2011-01-01
Abstract:The electrochemical behavior of SAE-1020 carbon steel in acidic simulation solutions containing H_2S with different concentrations of HCl at 90℃was investigated by mass loss method,electrochemical measurements, SEM observations and XRD.The results indicated that the cathodic depolarization was promoted greatly and the corrosion rate of carbon steel increased remarkably with the increase of HCl concentration in H_2S-containing solutions.Large numbers of corrosion holes formed on carbon steel in H_2S-containing solution without HCl,whereas only the uniform corrosion characteristic was observed on carbon steel surface in the simulation solutions containing different concentrations of HCl.Mackinawite was the sole corrosion product formed on the carbon steel surface in the H_2S-containing solutions with and without HCl.
-
A Study on the Corrosion Behavior of Carbon Steel Exposed to a H2S-Containing NH4Cl Medium
Hai-bo Wang,Yun Li,Guang-xu Cheng,Wei Wu,Yao-heng Zhang
DOI: https://doi.org/10.1007/s11665-018-3355-1
IF: 2.3
2018-01-01
Journal of Materials Engineering and Performance
Abstract:NH4Cl corrosion failure often occurs in the overhead systems of hydrotreaters, and this failure is always accompanied by the appearance of H2S. A combination of electrochemical and surface spectroscopic (SEM/EDS, AFM, XRD) techniques was used to investigate the effect of different factors, including the surface roughness, temperature, dissolved oxygen, pH and H2S concentration, on the corrosion behavior of carbon steel in an NH4Cl environment with the presence of H2S. The effect of H2S concentrations (at the ppm level) on the corrosion behavior of carbon steel was systematically revealed. The experimental results clearly indicated that the corrosion rate reached a minimum value at 10 ppm H2S. The steel surface was covered by a uniform corrosion product film in a 10 ppm H2S environment, and the corrosion product film was tight and protective. The ammonia from NH4Cl helped maintaining the protectiveness of the corrosion films in this environment. Dissolved oxygen mainly accelerated the cathodic reaction. The cathodic limiting current density increased with increasing temperature, and the anodic branch polarization curves were similar at different temperatures. The anodic current density decreased as the pH decreased, and the cathodic current density increased as the pH decreased. The absolute surface roughness (R (a)) of carbon steel increased from 132.856 nm at 72 h to 153.973 nm at 144 h, and the rougher surface resulted in a higher corrosion rate. The critical innovation in this research was that multiple influential factors were revealed in the NH4Cl environment with the presence of H2S.
-
The effect of H2S concentration on the corrosion behavior of carbon steel at 90°C
Junwen Tang,Yawei Shao,Jinbiao Guo,Tao Zhang,Guozhe Meng,Fuhui Wang
DOI: https://doi.org/10.1016/j.corsci.2010.02.004
IF: 7.72
2010-01-01
Corrosion Science
Abstract:The electrochemical behavior of SAE-1020 carbon steel in 0.25M Na2SO4 solution containing different concentrations of H2S at 90°C was investigated using the methods of weight loss, electrochemical measurements, scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the corrosion rate of carbon steel increased significantly with the increase of H2S concentration. H2S accelerated the corrosion rate of SAE-1020 carbon steel by a promoted hydrogen evolution reaction. Severe corrosion cavities were observed on the carbon steel surface in the solutions containing H2S due to cementites stripped off from the grain boundary. The loose corrosion products formed on the steel surfaces were composed of mackinawite.
-
The Effect of H(2)S Concentration on the Corrosion Behavior of Carbon Steel at 90 Degrees C
Jianqun Tang,Yawei Shao,J. B. Guo,T. Zhang,Guozhe Meng,F. H. Wang
2010-01-01
Abstract:The electrochemical behavior of SAE-1020 carbon steel in 0.25 M Na(2)SO(4) solution containing different concentrations of H(2)S at 90 degrees C was investigated using the methods of weight loss, electrochemical measurements, scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results showed that the corrosion rate of carbon steel increased significantly with the increase of H(2)S concentration. H(2)S accelerated the corrosion rate of SAE-1020 carbon steel by a promoted hydrogen evolution reaction. Severe corrosion cavities were observed on the carbon steel surface in the solutions containing H(2)S due to cementites stripped off from the grain boundary. The loose corrosion products formed on the steel surfaces were composed of mackinawite. (C) 2010 Elsevier Ltd. All rights reserved.
-
Effect of Cl− Accumulation on Corrosion Behavior of Steels in H2S/CO2 Methyldiethanolamine (MDEA) Gas Sweetening Aqueous Solution
Naiyan Zhang,Dezhi Zeng,Guoqing Xiao,Jianfeng Shang,Yuanzhi Liu,Decai Long,Qiyao He,Ambrish Singh
DOI: https://doi.org/10.1016/j.jngse.2016.02.055
IF: 5.285
2016-01-01
Journal of Natural Gas Science and Engineering
Abstract:Effects of Cl- accumulation on corrosion behavior of the three steels (20,304L and 316L) in H2S/CO2 MDEA desulfuring aqueous solution was investigated by using a HT (high temperature) autoclave, and the corrosion products were characterized by scanning electron microscopy (SEM), energy dispersive Xray spectroscopy (EDX) and X-ray diffraction technique (XRD). Electrochemical measurements such as polarization curve and electrochemical impedance spectroscopy were adopted to analyze the effects of Cl- concentration on the corrosion. Weight loss tests showed that corrosion rate of three steels (20, 304L and 316L) appeared as a reversal "v" shape and reached the peak at 20,000 mg/L Cl- content. SEM, EDX and XRD results showed that the corrosion scales were mainly FeS, FeS2 and FeCO3, and the corrosion process was mainly controlled by H2S, furthermore, CO2 corrosion further weakened as the chlorine ions content increased. Electrochemical studies suggested that, with the rise in chlorine ions content, the corrosion potential shifted negatively, and the activation and dissolution of mental anode accelerated, which can be attributed to the penetration and absorption effect of chloride ion. In addition, chlorine ions competitive absorption also played an important role in corrosion process. Therefore, to prolong the service life of desulfuring equipment, it is suggested that 20 steel not be used in units and facilities with large acid gas load at high temperature and the mass concentration of chloride ion content in the desurfuring MDEA solution should be controlled at a low level with the consideration of its complex effect. (C) 2016 Elsevier B.V. All rights reserved.
-
Effect of H_2S Concentration and Temperature on the Corrosion Behavior of Carbon Steel in NACE Solution
刘文会,董宇,刘建华,吴昊,于美,李松梅
DOI: https://doi.org/10.13374/j.issn1001-053x.2012.10.003
2012-01-01
Abstract:The electrochemical corrosion behavior of 20# carbon steel in NACE solutions containing different mass concentrations of H2S(0,95.61,103.22,and 224.16 mg·L-1) at different temperatures(25,35,and 45 ℃) was investigated by potentiodynamic polarization tests,electrochemical impedance spectroscopy(EIS),scanning electron microscopy(SEM),and energy dispersive spectroscopy(EDS).The formation mechanism of corrosion products was also discussed.It is found that the corrosion rate of the carbon steel increases significantly with the addition of a small amount of H2S in the NACE solution by promoting both the anodic iron dissolution and the cathodic hydrogen evolution.The corrosion current density of the carbon steel enhances with the increment of H2S concentration.As the temperature of the electrolyte solution increasing,the corrosion rate also increases.The outer loose corrosion products are mainly iron carbonate;but corrosion products formed on the steel surface are mainly composed of iron sulfides.
-
Corrosion behavior of carbon steel in H2S-CO2-H2O-methyldiethanolamine (MDEA) solution under the presence of chloride ions
Guiyang Wu,Xikui Gu,Wanwei Zhao,Rui Fan,Ting Mao
DOI: https://doi.org/10.1108/acmm-12-2020-2420
2021-07-26
Abstract:Purpose This paper aims to study the effect of chloride ions concentration on the corrosion behavior of carbon steel in methyldiethanolamine (MDEA) aqueous solution in the sight of different process parameters of purification plant. Design/methodology/approach Due to the decrease of filtration efficiency and separation efficiency, the chloride ion in the desulfurization solution is enriched. The corrosion behavior of carbon steel under chloride ion enrichment environment was studied by weight-loss method, electrochemical impedance spectroscopy, cyclic polarization curve, X-ray photoelectron spectroscopy and scanning electron microscopy. Findings The results show that temperature and hydrogen sulfide loads are the main factors of corrosion in CO2-MDEA-H2O-H2S environment. The enrichment of chloride ions reduces the corrosion rate at low temperature but promotes the corrosion rate at high temperature. The chloride concentration should be controlled below 3000 mg/L, and no pitting corrosion was found under the experimental conditions. Originality/value The effect of chloride ion enrichment on MDEA solution corrosion shows that at low temperature, the increase of chloride ion will reduce the acid gas load and increase the density of corrosion products, so as to reduce the corrosion; on the contrary, at high temperature, the density of corrosion products will decrease and the corrosion will be intensified as well. It is believed that the chloride ion should be controlled below 3000 mg/L according to the results of the tests.
metallurgy & metallurgical engineering
-
20 10 HIGH SALT CONCENTRATION EFFECTS ON CO 2 CORROSION AND H 2 S CORROSION
Haitao Fang,B. Brown,S. Neši
2009-01-01
Abstract:The general CO2 corrosion rates of C1018 carbon steel have been measured for NaCl concentrations 3 – 25 wt% at 20oC, pH 4.0, 5.0 and 6.0. The corrosion process was monitored by linear polarization resistance and potentiodynamic sweeps. AC impedance was used to measure and correct for solution resistance while weight loss was used to verify the corrosion rate magnitude. Experimental results showed that high salt concentrations decreased the general CO2 corrosion rate significantly and nonlinearly. Potentiodynamic sweep analysis shows that both cathodic and anodic processes were retarded. Flow velocity effects on general CO2 corrosion rate were minimized due to an increase of salt concentration. No effect of high salt concentration on initiation of localized attack was detected. A parallel research project was conducted to investigate the high salt concentration effect on H2S corrosion. The main objective was to study if the high concentration of chloride could initiate localized attack in a H2S system. Experiments were conducted in a nitrogen purged system with trace amount of H2S (50 ppm). Weight loss was used to measure corrosion rates. Scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDX) and X-ray diffraction (XRD) methods were used to characterize the morphology, composition and phase identity of the corrosion products. Experimental results show that high salt concentration significantly slowed down the reaction rate in H2S corrosion. Some pitting attack was found both in salt-free and high-salt conditions. Experimental results did not show evidence that chlorides can initiate localized corrosion in H2S systems.
-
Hydrogen Permeation of Pipeline Steel under Sour Condensate Film Condition
Mingliang Liu,Lei Zhang,Dapeng Li,Wei Chang,Min Lu,Xiaohu Zhang
2015-01-01
CORROSION
Abstract:Hydrogen permeation behavior of pipeline steel under different sour condensate film condition was investigated by in-situ testing. The effects of H2S corrosion product scales and the temperature of wet gas containing a high content of hydrogen sulfide on the hydrogen permeation of pipeline steel were studied by electrochemical methods. In wet gas conditions with a high content of hydrogen sulfide, ambient pressure corrosion simulation experiments were conducted in Devanathan-Stachurski cell tests to analyze the effects of different corrosion product scales and temperatures on hydrogen permeation. The corrosion products were studied by X-ray diffraction (XRD) and scanning electron microscope (SEM). The results show that the current density related to hydrogen permeation decreased and corrosion product scales became more protective with time. Besides, the current density related to hydrogen permeation increased as the temperature of wet gas increased. Key Word: hydrogen sulfide, sour condensate film, hydrogen permeation, pipeline steel INTRODUCTION Pipeline steel has been widely utilized in the oil and gas transfer due to its high strength and ductility. However, the H2S present in the oil and gas has greatly worsened the metal pipe corrosion environment and at the same time, increased the risk of hydrogen induced cracking. Cracking accidents of pipelines caused by H2S have increased in recent years. Although many international scholars have carried out a lot of work in this field, there is a lack of sufficient experience of corrosion of pipelines in wet gas containing high content of H2S. Therefore, corrosion and cracking related to pipeline environments that contain H2S and moisture has become more important in recent years. Corrosion or cracking of pipeline steel does not occur in H2S gas, it only occurs in wet H2S environments. Stress corrosion cracking of pipeline steel caused by hydrogen embrittlement can also occur in sour condensate film conditions. A wet H2S environment may consist of either an aqueous solution or a condensed thin liquid film environment, where the latter is where corrosion cracking behavior of pipeline steel really occurs. The H2S corrosion cracking behavior of pipeline steel under the two environment is very different.. Previous research based on simulated H2S solutions for hydrogen permeation and corrosion has not revealed the corrosion cracking mechanism of pipeline steel under the condition of wet gas containing H2S. For this research, in situ hydrogen penetration testing in wet H2S conditions were conducted and the corrosion products have been analyzed to explore the hydrogen permeation rate and the corrosion products that occurred under the conditions of condensate sour film and changing temperature. EXPERIMENT PROCEDURE API 5L X52QS pipeline steel was used in the experiments. The chemical composition of the steel is shown in Table 1. The steel specimens in the form of membranes were prepared having 0.6 mm thickness and 35 mm of diameter. The microstructure consists of ferrite and pearlite. Both sides of the membrane were ground with carborundum paper down to 1200 grit and polished. After pickling with 3 mol/L HCl, and degreasing with acetone, one side (detection side) of the steel membrane was deposited with a film of nickel in Watt’s bath of 250 g/L NiSO4·7H2O + 45 g/L NiCl2·6H2O +40 g/L H3BO3 using a cathodic current density of 10 mA/cm. In order to obtain different compositions of the corrosion product on the input side of the membrane, simulation corrosion experiments using the same experimental conditions as the hydrogen permeation tests (denoted by (1), (2), (3), and (4)) were conducted, as shown in Table 2, with specimens in the form of a diamond having 3 mm thickness and 1 mm of side length. Hydrogen permeation experiments were performed by using an electrochemical permeation technique originally developed by Devanathan and Stachurski to determine the hydrogen permeation through steel membranes. The cell was composed of two compartments, a hydrogen generating cell (input side) and a hydrogen oxidizing cell (detection side). The detection side was held at a constant potential of 300 mV vs. SCE in 0.2 mol/L NaOH solution, under which conditions the steel was considered to be at a passive potential. 1. Once the passive current reached a constant value, the input side was heated and sour condensate film formed on the membrane surface. The input side was exposed in sour condensed film containing high content H2S condition for a period lasting 14 d. At the same time, the current on the detection side was measured at set intervals, which gave a direct measurement of the hydrogen flow rate. Deoxygenation of the hydrogen oxidizing cell was carried out by purging with N2 for at least 8 hours. 2. Once the passive current reached a constant value, the input side was heated at different temperatures to get different sour condensate films formed on the membrane surfaces. The input side was exposed in sour condensed film containing high content H2S (1) American Petroleum Institute. conditions for a constant period lasting about 5.5 h. At the same time, the current on the detection side was measured, which gave a direct measurement of the hydrogen flow rate. Deoxygenation of hydrogen oxidizing cell was carried out by purging with N2 for at least 8 hours. Samples were characterized with a scanning electron microscope (SEM), an energy dispersive spectrometer (EDS) and an X-ray diffraction (XRD). RESULTS AND DISCUSSION Corrosion scales formed with exposure time The XRD patterns of corrosion product film formed on the surface of API 5L X52QS steel at different corrosion time on the condition of wet gas are shown in Figure 2. All of the corrosion products are comprised of different types of iron sulfide, such as Mackinawite (FeS1-x) and Pyrrhotite (Fe1-xS). The diffraction peak of matrix is very high, indicating that the corrosion product is thin. Figure 3 shows the SEM microphotography of the corrosion product film formed on the surface of API 5L X52QS steel at different exposure times. The surface morphology changed as the exposure time increased. The initial corrosion scale was smooth and mainly consisted of amorphous Mackinawite (Fe1-xS, denoted by M), as shown in Figure 3(a), and it was already present after a 2 d exposure in wet gas containing H2S. Some areas of the specimens were not completely covered with a corrosion scale (image not shown). Those exposed for at least 8 d however, were completely covered. The temperature of the wet gas was low, leading to a low rate of anodic dissolution and corrosion products growth. After 8 d exposure, the surface was complete covered with corrosion scale that had a very open and porous (sponge-like) structure, as shown in Figure 3(b). The corrosion scale was mainly consist of Mackinawite ((Fe1-xS, denoted by M). After 12 d exposure, the surface was still completely covered with corrosion scale that had a very open and porous (sponge-like) structure with larger crystal size, as shown in Figure 3(c). Besides, the areas covered on the sponge-like corrosion scale became larger, the scale mainly consisted of Mackinawite and a little Pyrrhotite (Fe1-xS+ FeS1-x, denoted by M+P). Specimens exposed for 14 d had corrosion scale consisting of Mackinawite and little Pyrrhotite (Fe1-xS + FeS1-x, denoted by M+P) with layers, as shown in Figure 3(d). Effects of corrosion scales on hydrogen permeation behavior The specimen was exposed to a sour condensate film for various periods of time up to 14 d, to get different corrosion scales on the specimen. Specimens with and without different corrosion scales were tested in the hydrogen permeation cells to measure the hydrogen permeation current density-time curves under free corrosion potentials with no cathodic charging on the input side, as shown in Figure 4. The thickness of the bare steel was 520 μm. The background current density of bare steel was less than 1.0 μA/cm. The input side of the cell, containing deionized water, was heated at a temperature of 35 C, then the high purity H2S gas was piped into the cell. The hydrogen permeation current appeared in a very short period time. For bare steel, amorphous Mackinawite scale, M scale, and M+P scale, the hydrogen permeation currents were 38.5 μA/cm, 29.8 μA/cm, 29 μA/cm, and 26.6 μA/cm, respectively. This indicates that the corrosion scales decreased the hydrogen concentration adsorbed on the surface. This means that under the condition of wet gas containing H2S, the corrosion product became more and more protective as the corrosion time increased at the temperature of 35 °C. Related research shows that for the same kind of material, the greater the hydrogen steady-state hydrogen permeation current is, the more severe the hydrogen damage is. According to the above test results, using the same conditions for hydrogen evolution, amorphous Mackinawite scale, M scale, and M+P scale, inhibited hydrogen adsorption on the surface in order. This indicates that these corrosion scales decrease the risk of hydrogen induced cracking for pipelines. Effects of temperature of wet gas on hydrogen permeation behavior The hydrogen permeation current density-time curves of API 5L X52QS steel at different temperatures of wet gas containing H2S are shown in Figure 5. Table 3 shows the parameters of hydrogen permeation for API 5L X52QS steel at different temperatures of wet gas containing H2S, where i∞ is steady-state hydrogen permeation current density, t0.63 is the time when it /i∞ = 0.63, J∞ is steady-state hydrogen diffusion flux, Φ is hydrogen permeability, and C is hydrogen concentration adsorbed on the surface. The thickness of the bare steel was 600 μm when the background current density of bare steel was less than 1.0 μA/cm. The input side of the cell containing deionized water was heated to different temperatures, then the high purity H2S gas was piped into the cell. The hydr
-
Corrosion Behaviour of 110SS Steel in Hydrochloric Acid and Blended Acid System at 200°C
Jinming Liu,Pingli Liu,Gang Xiong,Pengfei Chen,Juan Du,Ce Li,Yaoshun Yuan,Zixuan Zuo,Jinlong Li,Chengjie Wang
DOI: https://doi.org/10.1177/1478422x241277631
IF: 1.971
2024-01-01
Corrosion Engineering Science and Technology
Abstract:The influence of organic acids (formic acid, acetic acid) on the corrosion behaviour of 110SS steel, a hydrogen sulphide corrosion resistant alloy steel, in hydrochloric (HCl) acid environments was studied. The corrosion rates of 110SS steels in HCl acid and blended acid were measured using the high-temperature and high-pressure corrosion tester. Scanning electron microscopy was utilised to observe the morphology of corrosion products on steel samples corroded by different acid systems, and the energy dispersive X-ray spectrometer was used to analyse the elemental composition of the corrosion products. The corrosion morphology was observed using a 3D laser scanner. The results indicated that the corrosion rate of 110SS steel in HCl acid at 200 °C was an exponential function of HCl concentration. Reducing the HCl concentration significantly decreased the corrosion rate of 110SS steel. Organic acids and corrosion inhibitors synergistically reduced the corrosion of 110SS steel in HCl acid. Adding 3 wt.% organic acid to the 15 wt.% HCl acid system further reduced the corrosion rate, with a more pronounced effect observed in the HCl–formic acid system compared to the HCl–acetic acid system. Organic acids chemically adsorbed onto the steel surface and decomposed to produce CO, which hindered the attack of hydrogen ions on the metal. The added corrosion inhibitor and intensifier Sb2O3 resulted in the formation of a compact adsorption film on the steel surface, further inhibiting corrosion. The optimal mass ratio of HCl acid to organic acid was found to be 15% to 3%.
-
Effect of Temperature on Corrosion Behavior and Mechanism of S135 and G105 Steels in CO2/H2S Coexisting System
Kechao Gao,Suogui Shang,Zhi Zhang,Qiangyong Gao,Jinxin Ma,Wanying Liu
DOI: https://doi.org/10.3390/met12111848
IF: 2.695
2022-10-30
Metals
Abstract:The corrosive environment of oilfield condensate water was simulated at different temperatures with CO2/H2S. Weight-loss corrosion tests were conducted on S135 and G105 steels at different temperatures. The corrosion rates of the S135 and G105 were measured at room temperature, 100 °C and 180 °C. The phase structure of the corrosion products and the corrosion morphologies of the samples were characterized. The results show that the corrosion rates of the S135 and G105 increased at first and then decreased with the increase in temperature. The corrosion rates peaked at 100 °C, reaching 0.8463 mm/y and 0.8500 mm/y, respectively. CO2 was the main controlling factor in the corrosion. The corrosion products were FeS and FeCO3. The corrosion rate at room temperature was lower than that at 100 °C. The corrosion rate at the temperature of 180 °C was the lowest. The corrosion rates of the S135 and G105 were 0.2291 mm/y and 0.2309 mm/y, respectively. CO2 was not the main controlling factor in the corrosion. The corrosion product was FeS. High temperatures aggravated the carbon-steel corrosion further in the environment with the high concentration of CO2 and a loose corrosion-product film formed. The dense and uniform FeS corrosives formed and attached to the surface of the substrate, and inhibited corrosion. Dense and uniform FeS products formed on the surface of the steel with the increase in temperature. A small amount of H2S inhibited the progress of the corrosion.
materials science, multidisciplinary,metallurgy & metallurgical engineering
-
Corrosion-Mechanical Properties and Susceptibility to Hydrogenetaion of Pipe Steel in the Presence of Carbon Dioxide Gas and Hydrogen Sulphide in Environment
M. S. Khoma,V. I. Pokhmurskii,M. R. Chuchman,Kh. B. Vasyliv,V. R. Ivashkiv,N. B. Ratska
DOI: https://doi.org/10.1007/s11003-024-00764-z
2024-02-06
Materials Science
Abstract:The effect of different concentrations of CO 2 and H 2 S in a chloride-acetate solution on corrosion-mechanical properties of 17G1S-U steel was studied. In a solution saturated with CO 2 , the corrosion rate of steel was lower than in the presence of H 2 S, but increased over time due to the absence of protective carbonate films on the surface, plasticity parameters were 2–2.7 times lower than in air due to dimple surface damage. The corrosion rate and hydrogenation of steel was determined primarily by the hydrogen sulfide concentration in the environment. At a concentration of 100 mg/dm 3 , dense films of the troilite-mackinavite composition were formed, which inhibit corrosion. At higher concentrations, the corrosion rate increased due to the sulfides transformation and the formation of surface layers with defects. With an increase in the H 2 S concentration from 100 mg/dm 3 , the strength characteristics of steel decreased in three times, and plasticity decreased in 3–5 times.
materials science, multidisciplinary
-
Investigation of pH2S influence on 3% Cr tubing steel corrosion behaviours in CO2–H2S–Cl− environment
weili yan,jinxia deng,peng zhu,xianran xing
DOI: https://doi.org/10.1179/1743278215Y.0000000001
IF: 1.971
2015-01-01
Corrosion Engineering Science and Technology
Abstract:A series of experiments were conducted in autoclave to investigate corrosion properties of low Cr oil country tubular goods in CO2/H2S saturated brine solution (3 wt-% NaCl) at 90 degrees C. Test material is 3Cr-80, which is gradually accepted in oil and gas industry, especially for downhole tubing and casing. The CO2 partial pressure was fixed at 4.0 bar in all experiments, and the H2S partial pressure was varied from 0, 2, 4, 8, 20, 40 and 800 mbar to 4000 mbar (4 bar). The results show that when the pH(2)S varied at a lower range (2-40 mbar), 3Cr-80 materials' corrosion rates were restricted, and coupons' surface morphologies became glossy compared to the pure CO2 corrosion. Under the condition of pH(2)S=800 mbar, H2S no longer have a retardation effect on CO2 corrosion but acceleration. The average corrosion rate was higher than pure CO2 corrosion. When the pH(2)S rise to 4000 mbar (equal to the CO2 partial pressure), 3Cr corroded much more severe and serious mesa attack was observed.
-
Effect of Temperature and Pressure on Corrosion and Hydrogenation of Steel in Chloride-Acetate Environment with Different Concentrations of Hydrogen Sulfide and Carbon Dioxide
V. I. Pokhmurskii,M. S. Khoma,M. R. Chuchman,Kh. B. Vasyliv,N. B. Ratska
DOI: https://doi.org/10.1007/s11003-024-00806-6
2024-06-19
Materials Science
Abstract:Low-carbon pipe steel's corrosion rate and hydrogenation in a chloride-acetate solution with CO 2 /H 2 S mixtures at different temperatures and pressures were investigated. The rate of corrosion and hydrogenation depend on the H 2 S concentration and the properties of corrosion films. In a solution with a pressure ratio of and at the beginning of exposure at a pressure ratio of 3:1 corrosion slows down due to the formation of Fe 1+ x S mackinawite film. Over time, mackinawite transforms into hexagonal FeS troilite with an acicular structure, and the corrosion rate increases in approx. 2 times. The corrosion rate of steel at 60°C and 5 MPa in a solution with a pressure ratio of was twice as low as at 20°C and 0.1 MPa. A dense layer of cubic iron sulfide FeS crystals was formed on the surface, which reduces corrosion. The adsorption of hydrogen by the steel reduced in approx. 15 times as the temperature increases.
materials science, multidisciplinary
-
Synergistic Effect of the Total Acid Number, S, Cl, and H2O on the Corrosion of AISI 1020 in Acidic Environments
Shuoxun Shen,Zhirong Wang,Juncheng Jiang,Xingyan Cao,Peipei Sun,Yawei Lu,Rongrong Yang
DOI: https://doi.org/10.1021/acsomega.0c02219
IF: 4.1
2020-01-01
ACS Omega
Abstract:The corrosive environment in sulfur-containing equipment is often complicated and changeable. This study adopted the Taguchi method to optimize the immersion test, and the L27(313) orthogonal table was used to design an immersion corrosion experiment. The influence of four factors, namely, the total acid number (TAN), sulfur, chlorine, and water, on the corrosion of AISI 1020 in the oil phase was studied. It showed that the effect of chlorine is the most pronounced and that of sulfur is second followed by that of the TAN and H2O. It was also found that the effect of H2O exceeds that of the TAN after 336 h; meanwhile, the interaction between the four factors varies over time and stabilizes after 336 h. Moreover, corrosion rate curves reveal that the stable corrosion product film formed on the metal surface gradually slows down the corrosion process. Analysis of corrosion morphology and product composition was done by scanning electron microscopy and energy-dispersive X-ray spectroscopy. Overall, the synergistic effect of the corrosion rate changing with time provides a certain reference for the corrosion protection of sulfur-containing storage equipment.
-
Effect of Temperature and H<sub>2</sub>S Concentration on Corrosion of X52 Pipeline Steel in Acidic Solutions
Meng Li,Jian Qiu Wang,Wei Ke
DOI: https://doi.org/10.4028/www.scientific.net/msf.743-744.589
2013-01-01
Materials Science Forum
Abstract:The corrosion behavior of X52 pipeline steel in H 2 S solutions was investigated through immersion corrosion test which was carried out in a high temperature and high pressure autoclave at different temperatures and H 2 S concentrations. General corrosion rates were calculated based on the weight loss of samples. The morphology and the chemical composition of the corrosion products were obtained by Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS). The crystal structure of corrosion products was analyzed by X-Ray diffraction patterns (XRD). The corrosion products consisted mainly of the sulfide compounds (mackinawite, cubic ferrous sulfide, troilite and pyrrhotite). The corrosion products included two layers: the inner iron-rich layer and the outer sulfur-rich layer. Under H 2 S concentrations of 27g/L, the corrosion rate increased with the increase of temperature up to 90°C and then decreased at 120°C, finaly increased again. The corrosion rate first increased with H 2 S concentrations then decreased at 120°C. The structure and stability of the corrosion products due to different corrosion mechanism had a major impact on the corrosion rate. The corrosion resistance of the corrosion products increased as follows: mackinawite < cubic ferrous sulfide < troilite < pyrrhotite.
-
Impact of SO2 Concentration on the Corrosion Rate of X70 Steel and Iron in Water-Saturated Supercritical CO2 Mixed with SO2
Yong Xiang,Zhe Wang,Chao Xu,Chengchuan Zhou,Zheng Li,Weidou Ni
DOI: https://doi.org/10.1016/j.supflu.2011.06.007
2011-01-01
Abstract:The corrosion behavior of X70 steel and iron in water-saturated supercritical CO2 mixed with SO2 was investigated using weight-loss measurements. As a comparison, the instantaneous corrosion rate in the early stages for iron in the same corrosion environment was measured by resistance relaxation method. Surface analyzes using SEM/EDS, XRD and XPS were applied to study the morphology and chemical composition of the corroded sample surface. Weight-loss method results showed that the corrosion rate of X70 steel samples increased with SO2 concentration, while the corrosion rate increased before decreasing with SO2 concentration for iron sample. Comparing resistance relaxation method results with weight-loss method results, it is found that the instantaneous corrosion rate of iron is much higher than the uniform corrosion rate of the iron tablet specimens which are covered with thick corrosion product films after a long period of corrosion. The corrosion product films were mainly composed of FeSO4 and FeSO3 hydrates. The possible reaction mechanism under such environment was also analyzed, and the electrochemical reaction between the dissolved SO2 in the condensed water film with iron is the critical reaction step.
-
Effect of Temperature on the Corrosion Behavior of Carbon Steel in Hydrogen Sulphide Environments
Yameng Qi,Hongyun Luo,Shuqi Zheng,Changfeng Chen,Zhenguo Lv,Maoxian Xiong
DOI: https://doi.org/10.1016/s1452-3981(23)07914-2
IF: 1.541
2014-01-01
International Journal of Electrochemical Science
Abstract:The corrosion behavior of carbon steel exposed to hydrogen sulphide environment at different temperatures was investigated using the methods of weight-loss tests, electrochemical measurements, scanning electron microscopy (SEM) and X-ray diffraction (XRD). The results show that corrosion rate increased first and then decreased significantly with increasing temperature. As temperature increased, more fine and compact corrosion film was formed and the corrosion film converted from mackinawite to mackinawite/cubic FeS, indicating better protection to the steel. In addition, the solution equilibrium chemistry of dissolved H2S at different temperatures was also calculated and analyzed. Compared to the decrease of H+ concentration, corrosion films could play a more dominant role in the decrease in corrosion rate. Finally, a probable mechanism is proposed to interpret the reason for corrosion rate result of carbon steel at different temperatures based on the protectiveness of corrosion film and the variation of H+ concentration.