Phenolic Wastewater Treatment by Fenton Reagent in Gas-Liquid Fluidized Bed Reactor

ZHOU Li,ZHONG Hong,LI Xue-ping
2011-01-01
Journal of Central South University
Abstract:The removal rate of phenol from simulated wastewater was studied using gas-liquid fluidized bed with the Fenton reagent.The factors that affect the removal rate of phenol were investigated,including the initial concentrations of hydrogen peroxide c(H2O2) and c(Fe2+),the molar ratio of n(H2O2)/n(Fe2+),pH value,temperatures,reaction time,and the ventilation volume.The results show that optimal operating conditions are: c(H2O2)=12 mmol/L,n(H2O2)/n(Fe2+)=4:1,pH=4,temperature of 60 ℃,reaction time of 30 min and ventilation volume of 0.12 m3/h.Under these conditions,the phenol removal rate can reach 96%,and the mass concentration of phenol is 100 mg/L.