Effect of curing modes and light-cure times on microtensile bond strength of adhesives

WEI Wen-jia,MENG Xiang-feng,HUANG Zheng,LIU Xia,ZHOU Feng
DOI: https://doi.org/10.3969/j.issn.1003-1634.2012.06.020
2012-01-01
Abstract:Objective:This in vitro study evaluated the effect of curing modes and light-cure times on microtensile bond strength of adhesives.Method:40 extracted intact human molars were flattened to expose coronal dentin,and assigned into two groups,then prepared with one-step plus(OS)or clearfil-se-bond(SE).According to curing modes and light-cure times of adhesives,each group was divided into four subgroups(n=5):fast 10 s、fast 15 s、ramp 20 s and fast 20 s.Then the prepared teeth were restored with resin composites incrementally,After one week of water-storage,they were tested for microtensile bond strength.The failure models of beams were observed under a stereomicroscope.Data were analyzed by two-way ANOVA and LSD test(a=0.05).Result:In the OS group,there was no statistical difference between the microtensile bond strengths(μTBS) of fast 10 s、ramp 20 s and fast 20 s,and theμTBS of fast 15 s was significantly lower than those of ramp20s and fast 20 s.In the SE group,it was fast 20 s>ramp 20 s>fast 10 s and fast 15 s,and the μTBS of fast 20 s was far more higher than other subgroups.Conclusion: Within the limitations of this study,the soft-start technique could not improve μTBS of adhesives significantly.Being Cured in conventional curing model for 20 s can improve μTBS of clearfil-se-bond significantly,while one-step plus should be cured for 10 s in conventional cuing model.
What problem does this paper attempt to address?