ANALYSIS OF THERMAL PERFORMANCE OF EVACUATED TUBULAR SOLAR AIR COLLECTOR WITH INSERTED TUBES

Yuan Yingli,Li Yong,Dai Yanjun,Wang Ruzhu
DOI: https://doi.org/10.19912/j.0254-0096.2010.06.009
2010-01-01
Abstract:A 3D-unsteady numerical model for the evacuated tubular air collector with inserted metal tube was developed. The variation of radiant boundary with the time and space for the evacuated tube absorber was taken into account in the model,so it could simulate the practical condition better.This model was used to predict all-day performance of the evacuated tubular solar collector under varying radiant condition.Some experiments were carried out on evacuated tubular air collector with inserted tubes in order to analyze its thermal performance.Under typical spring and summer condition the collecting temperature,instantaneous efficiency and heat loss coefficient were 30 to 80℃,50%to 70%and 2 to 6W/(m~2·K),respectively.