Scheme analysis on the liquid product air separation plant using the cold energy of LNG

Yan Na,Li Yanzhong
IF: 2.134
2007-01-01
Cryogenics
Abstract:Two different modified air separation systems giving liquid products were designed and the results were compared.Instead of air and nitrogen expanding refrigeration unit,LNG cold energy was used respectively to pre-cool the material air and cycle nitrogen in the two systems.These two systems were simulated with Aspen Plus software and an exnergy analysis was performed.Compared with conventional method without using LNG,the new systems without external air or nitrogen cycle were simpler and more convenient.From the determined results it was found out that the consumed electric energy per-kilogram liquid product decreased about 49% for the first scheme and about 53% for the second scheme after using LNG cold energy,the exergy losses of these two new systems also decreased a lot,and the rational efficiency increased about 17% separately.Thus it can be stated that using this new modification in the air separation system much beneficial results were obtained than the contemporary ones.
What problem does this paper attempt to address?