Novel air separation unit cooled by liquefied natural gas cold energy and its performance analysis

JIN Tao,HU Jian-jun,CHEN Guo-bang,TANG Ke
DOI: https://doi.org/10.3785/j.issn.1008-973X.2007.05.028
2007-01-01
Abstract:A novel air separation unit cooled by liquefied natural gas(LNG) cold energy was proposed to recover the high-quality energy held in LNG due to its low temperature level while LNG being vaporized for applications at ambient temperatures.The rationality of this air separation process was analyzed from the thermodynamic viewpoint,followed by a detailed introduction of its process arrangement and characteristics,such as safety,operating pressure,adjustment and energy cost.Numerical simulation with Aspen Plus was carried out on a case of 10 000 m3/h oxygen production unit.The results showed its advantage in energy consumption per kilogram liquid oxygen,which was about 0.4 kW·h/kg,compared with the power input of 1.0 kW·h/kg in a conventional air separation unit.
What problem does this paper attempt to address?