Effect of Diameter of Graphite Particles on Infrared & 10.6μm Laser Attenuation Performance

LIU Guo-sheng,GUAN Hua,OUYANG De-hua,DU Xue-feng
DOI: https://doi.org/10.3969/j.issn.1003-1480.2009.02.003
2009-01-01
Abstract:For choosing a better material to interfere with infrared and laser, the infrared and 10.6μm laser transmissivity of 3 000 mesh, 6 000 mesh and 10 000 mesh graphite particles were tested in the smoke chamber. The results showed that all the graphite particles with different diameter had obvious attenuation function to infrared and 10.6μm laser.When the concentration of the smoke reached 1.5g·m~(-3), the transmissivity of the smoke to infrared and 10.6μm laser was lower than 30%. The attenuation ability of graphite particles increased gradually with the decreasing of the diameter of graphite particles. When the concentration of the smoke reached 3.5 g·m~(-3), the infrared thermal imager was completely defiladed.
What problem does this paper attempt to address?