Study on Failure Mode of Unbonded Post-tensioned Precast Short-pier Wall

Cai Xiao-ning,Meng Shao-ping,Sun Wei-wei
DOI: https://doi.org/10.3969/j.issn.1002-8412.2009.01.012
2009-01-01
Abstract:Unbonded post-tensioned precast short-pier wall contains the direct assembly short pier-wall and the hybrid assembly short-pier wall.The mechanical parameters ζ and α of unbonded post-tensioned precast short-pier wall are analyzed in this paper.The analytical results show that the type of structures can easily realize the good mechanism of energy dissipation and the initial elastic stiffness of the strctures only depends on the two parameters.Two specimens of unbonded post-tensioned precast short-pier wall are tested.One is the the direct assembly short-pier wall and the other is the hybrid assembly short-pier wall.The results of the experiments verify the issue above,and further indicate that the unbonded post-tensioned precast short-pier wall can be easily rehabilitated due to the small residual deformation of the structures under earthquake and concentrating around the connection zones.
What problem does this paper attempt to address?